Electroencephalographic source imaging: a prospective study of 152 operated epileptic patients
Open accessAbstract
Electroencephalography is mandatory to determine the epilepsy syndrome. However, for the precise localization of the irritative zone in patients with focal epilepsy, costly and sometimes cumbersome imaging techniques are used. Recent small studies using electric source imaging suggest that electroencephalography itself could be used to localize the focus. However, a large prospective validation study is missing. This study presents a cohort of 152 operated patients where electric source imaging was applied as part of the pre-surgical work-up allowing a comparison with the results from other methods. Patients (n = 152) with >1 year postoperative follow-up were studied prospectively. The sensitivity and specificity of each imaging method was defined by comparing the localization of the source maximum with the resected zone and surgical outcome. Electric source imaging had a sensitivity of 84% and a specificity of 88% if the electroencephalogram was recorded with a large number of electrodes (128-256 channels) and the individual magnetic resonance image was used as head model. These values compared favourably with those of structural magnetic resonance imaging (76% sensitivity, 53% specificity), positron emission tomography (69% sensitivity, 44% specificity) and ictal/interictal single-photon emission-computed tomography (58% sensitivity, 47% specificity). The sensitivity and specificity of electric source imaging decreased to 57% and 59%, respectively, with low number of electrodes (<32 channels) and a template head model. This study demonstrated the validity and clinical utility of electric source imaging in a large prospective study. Given the low cost and high flexibility of electroencephalographic systems even with high channel counts, we conclude that electric source imaging is a highly valuable tool in pre-surgical epilepsy evaluation.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Electrophysiological source imaging has been widely used in epilepsy source localization, including inter-ictal discharges.
“ESI has been widely used in epilepsy source localization, including inter-ictal discharges (76–81).”
From Electrophysiological source imaging: A noninvasive window to brain dynamics (2018) · cites this paper as [78]
In a study with over 150 patients, source imaging using high density EEG recordings had higher sensitivity and specificity compared to other imaging modalities such as MRI and PET.
“It has been shown in a study with over 150 patients that source imaging using high density EEG recordings, has higher sensitivity and specificity compared to other imaging modalities such as MRI and PET (78).”
From Electrophysiological source imaging: A noninvasive window to brain dynamics (2018) · cites this paper as [78]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Electroencephalography—Basic principles, clinical applications and related fields
(1982) · Journal of the Autonomic Nervous System · doi:10.1016/0165-1838(82)90067-4 · Cited by 3,449 · see citing works
Epilepsy: A Comprehensive Textbook
(2008) · JAMA · doi:10.1001/jama.300.4.443-a · Cited by 2,355 · see citing works
Michel, C. M., Murray, M. M., Lantz, G., Gonzalez, S., Spinelli, L., & de Peralta, R. G. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.06.001 · Cited by 1,663 · see citing works
Self-citationSpatiotemporal Analysis of Multichannel EEG: CARTOOL
Brunet, D., Murray, M. M., & Michel, C. M. (2011) · Computational Intelligence and Neuroscience · doi:10.1155/2011/813870 · Cited by 732 · see citing works
Self-citationWorrell, G. A., Gardner, A. B., Stead, S. M., Hu, S., Goerss, S., Cascino, G. J., Meyer, F. B., Marsh, R. W., & Litt, B. (2008) · Brain · doi:10.1093/brain/awn006 · Cited by 455 · see citing works
Interictal high-frequency oscillations (100–500 Hz) in the intracerebral EEG of epileptic patients
Urrestarazu, E., Chander, R., Dubeau, F., & Gotman, J. (2007) · Brain · doi:10.1093/brain/awm149 · Cited by 421 · see citing works
Electrical neuroimaging based on biophysical constraints
Menéndez, R. G. D. P., Murray, M. M., Michel, C. M., Martuzzi, R., & Andino, S. L. G. (2003) · NeuroImage · doi:10.1016/j.neuroimage.2003.09.051 · Cited by 364 · see citing works
Self-citationLocation of Sources of Evoked Scalp Potentials: Corrections for Skull and Scalp Thicknesses
Ary, J. P., Klein, S. A., & Fender, D. H. (1981) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1981.324817 · Cited by 320 · see citing works
Alarcón, G., Guy, C. N., Binnie, C. D., Walker, S., Elwes, R. D. C., & Polkey, C. E. (1994) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp.57.4.435 · Cited by 319 · see citing works
Manford, M., Fish, D. R., & Shorvon, S. D. (1996) · Brain · doi:10.1093/brain/119.1.17 · Cited by 303 · see citing works
Stereoelectroencephalography in presurgical assessment of MRI-negative epilepsy
McGonigal, A., Bartoloméi, F., Régis, J. M., Guye, M., Gavaret, M., Fonseca, A. T.-D., Dufour, H., Figarella-Branger, D. F., Girard, N. J., Peragut, J. C., et al. (2007) · Brain · doi:10.1093/brain/awm218 · Cited by 290 · see citing works
Sensitivity of MEG and EEG to Source Orientation
Hämäläinen, M., Ahlfors, S. P., Han, J., & Belliveau, J. W. (2010) · Digital Access to Scholarship at Harvard (DASH) (Harvard University) · Cited by 265 · see citing works
EEG source localization in focal epilepsy: Where are we now?
Plummer, C., Harvey, A. S., & Cook, M. J. (2007) · Epilepsia · doi:10.1111/j.1528-1167.2007.01381.x · Cited by 252 · see citing works
Functional imaging: II. Prediction of epilepsy surgery outcome
Knowlton, R. C., Elgavish, R. A., Bartolucci, A., Ojha, B., Limdi, N. A., Blount, J. P., Burneo, J. G., Hoef, L. V., Paige, A. L., Faught, E., et al. (2008) · Annals of Neurology · doi:10.1002/ana.21419 · Cited by 227 · see citing works
Grouiller, F., Thornton, R. C., Groening, K., Spinelli, L., Duncan, J. S., Schaller, K., Siniatchkin, M., Lemieux, L., Seeck, M., Michel, C. M., et al. (2011) · Brain · doi:10.1093/brain/awr156 · Cited by 199 · see citing works
Self-citationAn empirical Bayesian solution to the source reconstruction problem in EEG
Phillips, C. L. M., Mattout, J., Rugg, M. D., Maquet, P., & Friston, K. J. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2004.10.030 · Cited by 197 · see citing works
128-Channel EEG Source Imaging in Epilepsy: Clinical Yield and Localization Precision
Michel, C. M., Lantz, G., Spinelli, L., de Peralta, R. G., Landis, T., & Seeck, M. (2004) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200403000-00001 · Cited by 183 · see citing works
Self-citationElectromagnetic Inverse Solutions in Anatomically Constrained Spherical Head Models
Spinelli, L., Andino, S. L. G., Lantz, G., Seeck, M., & Michel, C. M. (2000) · Brain Topography · doi:10.1023/a:1026607118642 · Cited by 182 · see citing works
Self-citationInfluence of magnetic source imaging for planning intracranial EEG in epilepsy
Sutherling, W. W., Mamelak, A. N., Thyerlei, D., et al. (2008) · Neurology · doi:10.1212/01.wnl.0000326591.29858.1a · Cited by 177 · see citing works
Lantz, G., Spinelli, L., Seeck, M., Menéndez, R. G. D. P., Sottas, C. C., & Michel, C. M. (2003) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200309000-00003 · Cited by 172 · see citing works
Self-citationNeuronal networks in children with continuous spikes and waves during slow sleep
Siniatchkin, M., Groening, K., Moehring, J., Moeller, F., Boor, R., Brodbeck, V., Michel, C. M., Rodionov, R., Lemieux, L., & Stephani, U. (2010) · Brain · doi:10.1093/brain/awq183 · Cited by 160 · see citing works
Self-citationEffect of epilepsy magnetic source imaging on intracranial electrode placement
Knowlton, R. C., Razdan, S. N., Limdi, N. A., Elgavish, R. A., Killen, J., Blount, J. P., Burneo, J. G., Hoef, L. V., Paige, A. L., Faught, E., et al. (2009) · Annals of Neurology · doi:10.1002/ana.21660 · Cited by 152 · see citing works
Sensitivity and specificity of quantitative difference SPECT analysis in seizure localization.
Spanaki, M. V., Spencer, S. S., Corsi, M., et al. (1999) · PubMed · Cited by 150 · see citing works
EEG correlated functional MRI and postoperative outcome in focal epilepsy
Thornton, R., Laufs, H., Rodionov, R., Cannadathu, S., Carmichael, D. W., Vulliémoz, S., Salek‐Haddadi, A., McEvoy, A. W., Smith, S. J. M., Lhatoo, S. D., et al. (2010) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp.2009.196253 · Cited by 145 · see citing works
EEG Source Imaging in Pediatric Epilepsy Surgery: A New Perspective in Presurgical Workup
Sperli, F., Spinelli, L., Seeck, M., Kurian, M., Michel, C. M., & Lantz, G. (2006) · Epilepsia · doi:10.1111/j.1528-1167.2006.00550.x · Cited by 137 · see citing works
Self-citationElectrical source imaging for presurgical focus localization in epilepsy patients with normal MRI
Brodbeck, V., Spinelli, L., Lascano, A. M., Pollo, C., Schaller, K., Vargas, M. I., Wissmeyer, M., Michel, C. M., & Seeck, M. (2010) · Epilepsia · doi:10.1111/j.1528-1167.2010.02521.x · Cited by 128 · see citing works
Self-citationLocalizing value of scalp EEG spikes: A simultaneous scalp and intracranial study
Ray, A. K., Tao, J. X., Hawes‐Ebersole, S., & Ebersole, J. S. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.09.010 · Cited by 120 · see citing works
Multimodality imaging in the surgical treatment of children with nonlesional epilepsy
Seo, J. H., Holland, K. D., Rose, D. F., et al. (2010) · Neurology · doi:10.1212/wnl.0b013e318204a380 · Cited by 119 · see citing works
The spatio-temporal mapping of epileptic networks: Combination of EEG–fMRI and EEG source imaging
Vulliémoz, S., Thornton, R., Rodionov, R., Carmichael, D. W., Guye, M., Lhatoo, S. D., McEvoy, A. W., Spinelli, L., Michel, C. M., Duncan, J. S., et al. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.01.070 · Cited by 118 · see citing works
Self-citationQuantitative Interictal Subdural EEG Analyses in Children with Neocortical Epilepsy
Asano, E., Muzik, O., Shah, A. K., et al. (2003) · Epilepsia · doi:10.1046/j.1528-1157.2003.38902.x · Cited by 116 · see citing works
EEG and MEG in mesial temporal lobe epilepsy: Where do the spikes really come from?
Wennberg, R. A., Valiante, T. A., & Cheyne, D. O. (2011) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.11.019 · Cited by 111 · see citing works
Zumsteg, D., Friedman, A., Wennberg, R. A., & Wieser, H. G. (2005) · Clinical Neurophysiology · doi:10.1016/j.clinph.2005.08.009 · Cited by 110 · see citing works
Development of Volume Conductor and Source Models to Localize Epileptic Foci
Fuchs, M., Wagner, M., & Kastner, J. (2007) · Journal of Clinical Neurophysiology · doi:10.1097/wnp.0b013e318038fb3e · Cited by 109 · see citing works
Propagation patterns of temporal spikes
Emerson, R. G., Turner, C. A., Pedley, T. A., et al. (1995) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(94)00316-d · Cited by 102 · see citing works
Improving the Interpretation of Ictal Scalp EEG: BSS–CCA Algorithm for Muscle Artifact Removal
Vergult, A., Clercq, W. D., Palmini, A., et al. (2007) · Epilepsia · doi:10.1111/j.1528-1167.2007.01031.x · Cited by 98 · see citing works
Holmes, M. D., Tucker, D. M., Quiring, J., Hakimian, S., Miller, J. W., & Ojemann, J. G. (2010) · Neurosurgery · doi:10.1227/01.neu.0000363721.06177.07 · Cited by 97 · see citing works
Nayak, D. S., Valentı́n, A., Alarcón, G., Seoane, J. J. G., Brunnhuber, F., Juler, J., Polkey, C. E., & Binnie, C. D. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.01.009 · Cited by 86 · see citing works
Electric Source Imaging in Temporal Lobe Epilepsy
Gavaret, M., Badier, J., Marquis, P., Bartoloméi, F., & Chauvel, P. (2004) · Journal of Clinical Neurophysiology · doi:10.1097/01.wnp.0000139929.06455.82 · Cited by 86 · see citing works
Leijten, F. S. S., Huiskamp, G. J. M., Hilgersom, I., & van Huffelen, A. C. (2003) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200307000-00001 · Cited by 79 · see citing works
Groening, K., Brodbeck, V., Moeller, F., Wolff, S., van Baalen, A., Michel, C. M., Jansen, O., Boor, R., Wiegand, G., Stephani, U., et al. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.02.026 · Cited by 75 · see citing works
Self-citationAccuracy of EEG source imaging of epileptic spikes in patients with large brain lesions
Brodbeck, V., Lascano, A. M., Spinelli, L., Seeck, M., & Michel, C. M. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.01.011 · Cited by 75 · see citing works
Self-citationHuppertz, H., Hof, E., Klisch, J., Wagner, M., Lücking, C. H., & Kristeva-Feige, R. (2001) · NeuroImage · doi:10.1006/nimg.2000.0680 · Cited by 74 · see citing works
Continuous EEG source imaging enhances analysis of EEG-fMRI in focal epilepsy
Vulliémoz, S., Rodionov, R., Carmichael, D. W., Thornton, R., Guye, M., Lhatoo, S. D., Michel, C. M., Duncan, J. S., & Lemieux, L. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.11.055 · Cited by 64 · see citing works
Self-citationGavaret, M., Trébuchon, A., Bartoloméi, F., Marquis, P., McGonigal, A., Wendling, F., Régis, J. M., Badier, J., & Chauvel, P. (2008) · Epilepsia · doi:10.1111/j.1528-1167.2008.01742.x · Cited by 63 · see citing works
Interictal MEG/MSI in intractable mesial temporal lobe epilepsy: Spike yield and characterization
Kaiboriboon, K., Nagarajan, S. S., Mantle, M. M., & Kirsch, H. E. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.12.001 · Cited by 61 · see citing works
Lantz, G., Menéndez, R. G. D. P., Andino, S. L. G., & Michel, C. M. (2001) · Brain Topography · doi:10.1023/a:1012996930489 · Cited by 59 · see citing works
Self-citationLocalization of cortico-peripheral coherence with electroencephalography
Guggisberg, A. G., Dalal, S. S., Zumer, J. M., Wong, D. D. E., Dubovik, S., Michel, C. M., & Schnider, A. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.05.076 · Cited by 57 · see citing works
Self-citationPositron emission tomography and single photon emission computed tomography in epilepsy care
Henry, T. R., & Heertum, R. L. V. (2003) · Seminars in Nuclear Medicine · doi:10.1053/snuc.2003.127301 · Cited by 56 · see citing works
EEG Mapping and Source Imaging
Michel, C. M., & He, B. (2017) · Oxford University Press eBooks · doi:10.1093/med/9780190228484.003.0045 · Cited by 55 · see citing works
Self-citationRapid consolidation and the human hippocampus: Intracranial recordings confirm surface EEG
Nahum, L., Gabriel, D., Spinelli, L., Momjian, S., Seeck, M., Michel, C. M., & Schnider, A. (2010) · Hippocampus · doi:10.1002/hipo.20819 · Cited by 40 · see citing works
Self-citationAdvances in Spike Localization with EEG Dipole Modeling
Rose, S., & Ebersole, J. S. (2009) · Clinical EEG and Neuroscience · doi:10.1177/155005940904000410 · Cited by 37 · see citing works
Zumsteg, D., Friedman, A., Wieser, H. G., et al. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2005.11.014 · Cited by 27 · see citing works
A Method for Locating Scalp Electrodes in Spherical Coordinates
Ary, J. P., Darcey, T. M., & Fender, D. H. (1981) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1981.324684 · Cited by 20 · see citing works
Source Localization of Temporal Lobe Epilepsy Using PCA—LORETA Analysis on Ictal EEG Recordings
Stern, Y., Neufeld, M. Y., Kipervasser, S., et al. (2009) · Journal of Clinical Neurophysiology · doi:10.1097/wnp.0b013e31819b3bf2 · Cited by 19 · see citing works
International federation of societies for electroencephalography and clinical neurophysiology
(1974) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(74)90096-0 · Cited by 14 · see citing works
Vth International Congress of electroencephalography and clinical neurophysiology
Cobb, W. A. (1964) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(64)90020-3 · Cited by 6 · see citing works
Sensitivity of MEG and EEG to source orientation
Ahlfors, S. P., Han, J., Belliveau, J. W., & Hämäläinen, M. S. (2010) · Brain Topography · doi:10.1007/s10548-010-0154-x · Cited by 1 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
The standardized EEG electrode array of the IFCN
Seeck, M., Koessler, L., Bast, T., Leijten, F., Michel, C., Baumgartner, C., He, B., & Beniczky, S. (2017) · Clinical Neurophysiology · doi:10.1016/j.clinph.2017.06.254 · Cited by 489 · see citing works
Self-citationElectrophysiological source imaging: A noninvasive window to brain dynamics
He, B., Sohrabpour, A., Brown, E., & Liu, Z. (2018) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-062117-120853 · Cited by 297 · see citing works
(2019) · Handbook of clinical neurology · doi:10.1016/b978-0-444-64032-1.00006-0 · Cited by 134 · see citing works
Self-citationCoito, A., Michel, C. M., van Mierlo, P., Vulliemoz, S., & Plomp, G. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2619665 · Cited by 75 · see citing works
Self-citationSohrabpour, A., Ye, S., Worrell, G. A., Zhang, W., & He, B. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2616474 · Cited by 59 · see citing works
A review on brain imaging techniques for BCI applications
Bhattacharyya, S., Khasnobish, A., Ghosh, P., Mazumder, A., & Tibarewala, D. N. (2017) · Medical Imaging · doi:10.4018/978-1-5225-0571-6.ch012 · Cited by 8 · see citing works
- Authors
- Brodbeck, V., Spinelli, L., Lascano, A. M., Wissmeier, M., Vargas, M.-I., Vulliemoz, S., Pollo, C., Schaller, K., Michel, C. M., & Seeck, M.
- Affiliations
- University of Geneva (CH)
- University Hospital of Geneva (CH)
- Centre Hospitalier Universitaire Vaudois (CH)
- Corresponding author
- Seeck, M.
- Venue
- Brain
- Publisher
- Oxford University Press (OUP)
- Published
- 2011-10-01
- Volume
- 134
- Issue
- 10
- Pages
- 2887-2897
- ISSN
- 0006-8950 (ISSN-L)
- 1460-2156
- PMC
- PMC3187544
- OpenAlex
- W2134353725
- Cited by
- 427
- References
- 57
- Citations by year
- 2026: 11 · 2025: 28 · 2024: 18 · 2023: 43 · 2022: 27 · 2021: 37 · 2020: 27 · 2019: 41 · 2018: 32 · 2017: 30 · 2016: 29 · 2015: 37 · 2014: 27 · 2013: 20 · 2012: 17
- FWCI
- 14.44
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by-nc
- Locations
- Brain (publishedVersion, cc-by-nc)
- Europe PMC (PubMed Central) (publishedVersion, cc-by-nc)
- PubMed Central (publishedVersion, cc-by-nc)
- PubMed (publishedVersion)
- Archive ouverte UNIGE (University of Geneva) (publishedVersion)
- reroDoc Digital Library (submittedVersion)
- IRIS (submittedVersion)
- SERVAL (Université de Lausanne) (submittedVersion, other-oa)
- Archive ouverte UNIGE (University of Geneva) (submittedVersion, cc-by)
- Funders
- National Science Foundation
- Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung (33CM30, 124089, 122073, 320030)
- Centre d'Imagerie BioMédicale
- Topics
- Health Sciences › Medicine › Psychiatry and Mental health › Epilepsy research and treatment
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Health Sciences › Medicine › Neurology › Neurological disorders and treatments
- Keywords
- EEG source localization, focal epilepsy, epileptic focus localization, preoperative assessment, surgical outcomes, PET, SPECT, sensitivity and specificity, epilepsy surgery
- MeSH terms
- Adolescent, Adult, Brain Mapping, Cerebral Cortex, Child, Child, Preschool, Electroencephalography, Epilepsy, Female, Humans, Infant, Male, Middle Aged, Prospective Studies, Radionuclide Imaging, Sensitivity and Specificity, Reproducibility of Results, Databases, Factual
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review