CoChat

Prediction of malignant middle cerebral artery infarction by magnetic resonance imaging within 6 hours of symptom onset: A prospective multicenter observational study

Thomalla, Götz, Hartmann, Frank, Juettler, Eric, Singer, Oliver C., Lehnhardt, Fritz‐Georg, Köhrmann, Martin, Kersten, Jan F., Krützelmann, Anna, Humpich, Marek C., Sobesky, Jan, Gerloff, Christian, Villringer, Arno, Fiehler, Jens, Neumann‐Haefelin, Tobias, Schellinger, Peter D., Röther, Joachim, for the Clinical Trial Net of the German Competence Network Stroke · 2010 · Annals of Neurology
Cited by 245

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Objective: Early identification of patients at risk of space‐occupying “malignant” middle cerebral artery (MCA) infarction (MMI) is needed to enable timely decision for potentially life‐saving treatment such as decompressive hemicraniectomy. We tested the hypothesis that acute stroke magnetic resonance imaging (MRI) predicts MMI within 6 hours of stroke onset. Methods: In a prospective, multicenter, observational cohort study patients with acute ischemic stroke and MCA main stem occlusion were studied by MRI including diffusion‐weighted imaging (DWI), perfusion imaging (PI), and MR‐angiography within 6 hours of symptom onset. Multivariate regression analysis was used to identify clinical and imaging predictors of MMI. Results: Of 140 patients included, 27 (19.3%) developed MMI. The following parameters were identified as independent predictors of MMI: larger acute DWI lesion volume (per 1 ml odds ratio [OR] 1.04, 95% confidence interval [CI] 1.02–1.06; p < 0.001), combined MCA + internal carotid artery occlusion (5.38, 1.55–18.68; p = 0.008), and severity of neurological deficit on admission assessed by the National Institutes of Health Stroke Scale score (per 1 point 1.16, 1.00–1.35; p = 0.053). The prespecified threshold of a DWI lesion volume >82 ml predicted MMI with high specificity (0.98, 95% CI 0.94–1.00), negative predictive value (0.90, 0.83–0.94), and positive predictive value (0.88, 0.62–0.98), but sensitivity was low (0.52, 0.32–0.71). Interpretation: Stroke MRI on admission predicts malignant course in severe MCA stroke with high positive and negative predictive value and may help in guiding treatment decisions, such as decompressive surgery. In a subset of patients with small initial DWI lesion volumes, repeated diagnostic tests are required. ANN NEUROL 2010

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/ana.22125

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 245

Metadata

Authors
Thomalla, G., Hartmann, F., Juettler, E., Singer, O. C., Lehnhardt, F., Köhrmann, M., Kersten, J. F., Krützelmann, A., Humpich, M. C., Sobesky, J., Gerloff, C., Villringer, A., Fiehler, J., Neumann‐Haefelin, T., Schellinger, P. D., Röther, J., & for the Clinical Trial Net of the German Competence Network Stroke
Venue
Annals of Neurology
Publisher
Wiley
Published
2010-09-23
Volume
68
Issue
4
Pages
435-445
ISSN
  • 0364-5134 (ISSN-L)
  • 1531-8249
OpenAlex
W1990024475
Cited by
245
References
3
FWCI
6.50
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Prediction of malignant middle cerebral artery infarction by magnetic resonance imaging within 6 hours of symptom onset: A prospective multicenter observational study. https://app.cochat.ai/papers/10.1002/ana.22125
The paper
Thomalla, G., Hartmann, F., Juettler, E., Singer, O. C., Lehnhardt, F., Köhrmann, M., Kersten, J. F., Krützelmann, A., Humpich, M. C., Sobesky, J., Gerloff, C., Villringer, A., Fiehler, J., Neumann‐Haefelin, T., Schellinger, P. D., Röther, J., & for the Clinical Trial Net of the German Competence Network Stroke. (2010). Prediction of malignant middle cerebral artery infarction by magnetic resonance imaging within 6 hours of symptom onset: A prospective multicenter observational study. Annals of Neurology. https://doi.org/10.1002/ana.22125

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.