Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 203

The DOI matches its Crossref record.

Clinically distinct electroencephalographic phenotypes of early myoclonus after cardiac arrest

Open access
Elmer, Jonathan, Rittenberger, Jon C., Faro, John, Molyneaux, Bradley J., Popescu, Alexandra, Callaway, Clifton W., Baldwin, Maria, for the Pittsburgh Post‐Cardiac Arrest Service · 2016 · Annals of Neurology

Abstract

Objective: We tested the hypothesis that there are readily classifiable electroencephalographic (EEG) phenotypes of early postanoxic multifocal myoclonus (PAMM) that develop after cardiac arrest. Methods: We studied a cohort of consecutive comatose patients treated after cardiac arrest from January 2012 to February 2015. For patients with clinically evident myoclonus before awakening, 2 expert physicians reviewed and classified all EEG recordings. Major categories included: Pattern 1, suppression‐burst background with high‐amplitude polyspikes in lockstep with myoclonic jerks; and Pattern 2, continuous background with narrow, vertex spike‐wave discharges in lockstep with myoclonic jerks. Other patterns were subcortical myoclonus and unclassifiable. We compared population characteristics and outcomes across these EEG subtypes. Results: Overall, 401 patients were included, of whom 69 (16%) had early myoclonus. Among these patients, Pattern 1 was the most common, occurring in 48 patients (74%), whereas Pattern 2 occurred in 8 patients (12%). The remaining patients had subcortical myoclonus (n = 2, 3%) or other patterns (n = 7, 11%). No patients with Pattern 1, subcortical myoclonus, or other patterns survived with favorable outcome. By contrast, 4 of 8 patients (50%) with Pattern 2 on EEG survived, and 4 of 4 (100%) survivors had favorable outcomes despite remaining comatose for 1 to 2 weeks postarrest. Interpretation: Early PAMM is common after cardiac arrest. We describe 2 distinct patterns with distinct prognostic significances. For patients with Pattern 1 EEGs, it may be appropriate to abandon our current clinical standard of aggressive therapy with conventional antiepileptic therapy in favor of early limitation of care or novel neuroprotective strategies. Ann Neurol 2016;80:175–184

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/ana.24697

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 203

Metadata

Authors
Elmer, J., Rittenberger, J. C., Faro, J., Molyneaux, B. J., Popescu, A., Callaway, C. W., Baldwin, M., & Service, F. T. P. P. A.
Venue
Annals of Neurology
Publisher
Wiley
Published
2016-06-28
Volume
80
Issue
2
Pages
175-184
ISSN
  • 0364-5134 (ISSN-L)
  • 1531-8249
OpenAlex
W2471643128
Cited by
203
References
0
FWCI
25.23
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Clinically distinct electroencephalographic phenotypes of early myoclonus after cardiac arrest. https://app.cochat.ai/papers/10.1002/ana.24697
The paper
Elmer, J., Rittenberger, J. C., Faro, J., Molyneaux, B. J., Popescu, A., Callaway, C. W., Baldwin, M., & Service, F. T. P. P. A. (2016). Clinically distinct electroencephalographic phenotypes of early myoclonus after cardiac arrest. Annals of Neurology. https://doi.org/10.1002/ana.24697

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.