CoChat

123I‐2β‐carbomethoxy‐3β‐(4‐iodophenyl)‐N‐(3‐fluoropropyl) nortropane single photon emission computed tomography and 123I‐metaiodobenzylguanidine myocardial scintigraphy in differentiating dementia with lewy bodies from other dementias: A comparative study

Open access
Tiraboschi, Pietro, Corso, Angelo, Guerra, Ugo Paolo, Nobili, Flavio, Piccardo, Arnoldo, Calcagni, Maria Lucia, Volterrani, Duccio, Cecchin, Diego, Tettamanti, Mauro, Antelmi, Luigi, Vidale, Simone, Sacco, Leonardo, Merello, Maria, Stefanini, Stefano, Micheli, Anna, Vai, Paola, Capitanio, Selene, Gabanelli, Sara Vincenzina, Riva, Riccardo, Pinto, Patrizia, Biffi, Ave Maria, Muscio, Cristina, for the SCILLA Working Group · 2016 · Annals of Neurology
Cited by 52

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Objective: To compare the diagnostic value of striatal 123 I‐2β‐carbomethoxy‐3β‐(4‐iodophenyl)‐N‐(3‐fluoropropyl) nortropane (123 I‐FP‐CIT) single photon emission computed tomography (SPECT) and 123 I‐metaiodobenzylguanidine (123 I‐MIBG) myocardial scintigraphy in differentiating dementia with Lewy bodies (DLB) from other dementia types. Methods: This prospective longitudinal study included 30 patients with a clinical diagnosis of DLB and 29 patients with non‐DLB dementia (Alzheimer disease, n = 16; behavioral variant frontotemporal dementia, n = 13). All patients underwent 123 I‐FP‐CIT SPECT and 123 I‐MIBG myocardial scintigraphy within a few weeks of clinical diagnosis. All diagnoses at each center were agreed upon by the local clinician and an independent expert, both unaware of imaging data, and re‐evaluated after 12 months. Each image was visually classified as either normal or abnormal by 3 independent nuclear physicians blinded to patients' clinical data. Results: Overall, sensitivity and specificity to DLB were respectively 93% and 100% for 123 I‐MIBG myocardial scintigraphy, and 90% and 76% for 123 I‐FP‐CIT SPECT. Lower specificity of striatal compared to myocardial imaging was due to decreased 123 I‐FP‐CIT uptake in 7 non‐DLB subjects (3 with concomitant parkinsonism) who had normal 123 I‐MIBG myocardial uptake. Notably, in our non‐DLB group, myocardial imaging gave no false‐positive readings even in those subjects (n = 7) with concurrent medical illnesses (diabetes and/or heart disease) supposed to potentially interfere with 123 I‐MIBG uptake. Interpretation: 123 I‐FP‐CIT SPECT and 123 I‐MIBG myocardial scintigraphy have similar sensitivity for detecting DLB, but the latter appears to be more specific for excluding non‐DLB dementias, especially when parkinsonism is the only “core feature” exhibited by the patient. Our data also indicate that the potential confounding effects of diabetes and heart disease on 123 I‐MIBG myocardial scintigraphy results might have been overestimated. Ann Neurol 2016;80:368–378

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/ana.24717

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

Metadata

Authors
Tiraboschi, P., Corso, A., Guerra, U. P., Nobili, F., Piccardo, A., Calcagni, M. L., Volterrani, D., Cecchin, D., Tettamanti, M., Antelmi, L., Vidale, S., Sacco, L., Merello, M., Stefanini, S., Micheli, A., Vai, P., Capitanio, S., Gabanelli, S. V., Riva, R., Pinto, P., Biffi, A. M., Muscio, C., & for the SCILLA Working Group
Venue
Annals of Neurology
Publisher
Wiley
Published
2016-08-02
Volume
80
Issue
3
Pages
368-378
ISSN
  • 0364-5134 (ISSN-L)
  • 1531-8249
OpenAlex
W2473280862
Cited by
52
References
4
FWCI
6.73
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.