Controlled release of dopamine from a polymeric brain implant: In vivo characterization
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Intracerebral microdialysis was used to evaluate the long‐term in vivo release of dopamine from ethylene‐vinyl acetate (EV Ac)‐dopamine copolymer matrix discs for up to 65 days following striatal implantation. Dopamine release occurred through a single cavity present on one side of the disc, which was otherwise fully coated with an additional, impermeable layer of EV Ac. At 20 days following implantation of the device, extracellular concentrations of dopamine within the striatum reached micromolar levels, over 200‐fold greater than control values. Release of dopamine was shown to be stable and maintained for the 2‐month duration of the experiment. Histological examination confirmed the biocompatible nature of the implant. There are potential applications of this technology to the treatment of Parkinson's disease and other neurological and psychiatric disorders.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Leong, K. W., Brott, B. C., & Langer, R. (1985) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820190806 · Cited by 541
Self-citation
Cited by
Langer, R. (1990) · Science · doi:10.1126/science.2218494 · Cited by 1,778
Self-citationApproaches to neural tissue engineering using scaffolds for drug delivery
Willerth, S. M., & Sakiyama-Elbert, S. E. (2007) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.03.014 · Cited by 392
Therapeutic applications of implantable drug delivery systems
Dash, A., & Cudworth, G. (1998) · Journal of Pharmacological and Toxicological Methods · doi:10.1016/s1056-8719(98)00027-6 · Cited by 358
Polypeptide growth factors: targeted delivery systems
Nimni, M. E. (1997) · Biomaterials · doi:10.1016/s0142-9612(97)00050-1 · Cited by 260
Cabodi, M., Choi, N. W., Gleghorn, J. P., Lee, C. S. D., Bonassar, L. J., & Stroock, A. D. (2005) · Journal of the American Chemical Society · doi:10.1021/ja054820t · Cited by 234
Controlled release for local delivery of drugs: barriers and models
Weiser, J. R., & Saltzman, W. M. (2014) · Journal of Controlled Release · doi:10.1016/j.jconrel.2014.04.048 · Cited by 225
Self-citationApplications of ethylene vinyl acetate copolymers (EVA) in drug delivery systems
Schneider, C., Langer, R., Loveday, D., & Hair, D. (2017) · Journal of Controlled Release · doi:10.1016/j.jconrel.2017.08.004 · Cited by 209
Self-citationPolymeric implants for cancer chemotherapy
Fung, L. K., & Saltzman, W. M. (1997) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(97)00036-7 · Cited by 198
Self-citationBiodegradation and brain tissue reaction to poly(D,L-lactide-co-glycolide) microspheres
Menei, P., Daniel, V, Montero-Menei, C., Brouillard, M., Pouplard-Barthelaix, A., & Benoit, J. P. (1993) · Biomaterials · doi:10.1016/0142-9612(93)90151-q · Cited by 180
Drugs released from polymers: diffusion and elimination in brain tissue
Saltzman, W. M., & Radomsky, M. L. (1991) · Chemical Engineering Science · doi:10.1016/0009-2509(91)80036-x · Cited by 177
Self-citationDevelopment of microspheres for neurological disorders: From basics to clinical applications
Benoit, J.-P., Faisant, N., Venier-Julienne, M.-C., & Menei, P. (2000) · Journal of Controlled Release · doi:10.1016/s0168-3659(99)00250-3 · Cited by 166
Sirianni, R. W., Olausson, P., Chiu, A. S., Taylor, J. R., & Saltzman, W. M. (2010) · Brain Research · doi:10.1016/j.brainres.2010.01.041 · Cited by 51
“The disks were stored at −20 °C until use.”
BackgroundMethodSelf-citation
Metadata
- Authors
- During, M. J., Freese, A., Sabel, B. A., Saltzman, W. M., Deutch, A., Roth, R. H., & Langer, R.
- Venue
- Annals of Neurology
- Publisher
- Wiley
- Published
- 1989-04
- Volume
- 25
- Issue
- 4
- Pages
- 351-356
- ISSN
- 0364-5134 (ISSN-L)
- 1531-8249
- OpenAlex
- W2025940959
- Cited by
- 103
- References
- 1
- FWCI
- 14.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.