Proton nuclear magnetic resonance spectroscopic imaging of human temporal lobe epilepsy at 4.1 T
The DOI matches its Crossref record.
Abstract
We performed proton magnetic resonance spectroscopic imaging (MRSI) at high magnetic field (4.1 T) to study N‐acetylaspartate, creatine, and choline levels in the brains of normal control subjects and patients with intractable temporal lobe epilepsy. We compared the results of MRSI to those of other presurgical techniques to determine the sensitivity of this method in the lateralization of the epileptic focus. The normal hippocampal creatine—N‐acetylaspartate ratio was 0.71 ± 0.14 with no differences between left and right. Using the mean control hippocampal creatine—N‐acetylaspartate ratio plus 2 standard deviations to identify statistically significant changes, we found lateralizing metabolic abnormalities corresponding to the operated temporal lobe in all patients. Four patients (40%) had contralateral abnormalities, and 2 of them had bilateral independent seizure onset confirmed by intracranial electroencephalographic studies. Statistically significant increases in the choline—N‐acetylaspartate ratio in comparison to healthy volunteers were observed in 8 of the 10 patients. With the creatine—N‐acetylaspartate ratio, MRSI demonstrated a 100% sensitivity compared to magnetic resonance imaging, which identified pathology in 70% of the patients. These findings suggest that proton MRSI yields a distinctive metabolic profile in patients with temporal lobe epilepsy and is sensitive in detecting bilateral metabolic abnormalities in some patients. These preliminary findings suggest that MRSI is more sensitive than magnetic resonance imaging in the lateralization of epileptic foci in temporal lobe epilepsy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
7T vs. 4T: RF power, homogeneity, and signal-to-noise comparison in head images
Vaughan, J. T., Garwood, M., Collins, C. M., Liu, W., DelaBarre, L., Adriany, G., Andersen, P., Merkle, H., Goebel, R., Smith, M. B., et al. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1156 · Cited by 890
Kowal, C., DeGiorgio, L. A., Nakaoka, T., Hetherington, H., Huerta, P. T., Diamond, B., & Volpe, B. T. (2004) · Immunity · doi:10.1016/j.immuni.2004.07.011 · Cited by 405
Self-citationNeuroimaging evidence of progressive neuronal loss and dysfunction in temporal lobe epilepsy
Tasch, E., Cendes, F., Li, L. M., Dubeau, F., Andermann, F., & Arnold, D. L. (1999) · Annals of Neurology · doi:10.1002/1531-8249(199905)45:5<568::aid-ana4>3.0.co;2-p · Cited by 274
(1996) · American Journal of Psychiatry · doi:10.1176/ajp.153.12.1554 · Cited by 259
Hugg, J. W., Kuzniecky, R. I., Gilliam, F. G., Faught, R. E., Morawetz, R. B., & Hetherington, H. P. (1996) · Annals of Neurology · doi:10.1002/ana.410400215 · Cited by 217
Self-citation
Metadata
- Authors
- Hetherington, H., Kuzniecky, R., Pan, J., Mason, G., Morawetz, R., Harris, C., Faught, E., Vaughan, T., & Pohost, G.
- Venue
- Annals of Neurology
- Publisher
- Wiley
- Published
- 1995-09
- Volume
- 38
- Issue
- 3
- Pages
- 396-404
- ISSN
- 0364-5134 (ISSN-L)
- 1531-8249
- OpenAlex
- W2006355389
- Cited by
- 127
- References
- 0
- FWCI
- 11.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Proton nuclear magnetic resonance spectroscopic imaging of human temporal lobe epilepsy at 4.1 T. https://app.cochat.ai/papers/10.1002/ana.410380309
- The paper
- Hetherington, H., Kuzniecky, R., Pan, J., Mason, G., Morawetz, R., Harris, C., Faught, E., Vaughan, T., & Pohost, G. (1995). Proton nuclear magnetic resonance spectroscopic imaging of human temporal lobe epilepsy at 4.1 T. Annals of Neurology. https://doi.org/10.1002/ana.410380309
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.