The DOI matches its Crossref record.
A Glucose‐Selective Molecular Fluorescence Sensor
Abstract
Low concentrations of D-fructose and D-galactose do not hinder the detection of D-glucose with the fluorescence sensor 1. The diboronic acid 1 is easy to synthesize and forms a cleft structure in which monosaccharides bind with differing selectivity. The saccharide-diboronic acid 1:1 complexes are readily detected by their fluorescence.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Kirkman, M. S., Lernmark, A., Metzger, B. E., & Nathan, D. M. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2010.161596 · Cited by 1,360
Luminescent sensors and switches in the early 21st century
Callan, J. F., de Silva, A. P., & Magri, D. C. (2005) · Tetrahedron · doi:10.1016/j.tet.2005.05.043 · Cited by 1,123
Recent advances in electrochemical non-enzymatic glucose sensors – A review
Hwang, D.-W., Lee, S., Seo, M., & Chung, T. D. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2018.05.051 · Cited by 788
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Kirkman, M. S., Lernmark, A., Metzger, B. E., & Nathan, D. M. (2011) · Diabetes Care · doi:10.2337/dc11-9998 · Cited by 718
Fluorescence-based glucose sensors
Pickup, J. C., Hussain, F., Evans, N. D., Rolinski, O. J., & Birch, D. J. S. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.10.002 · Cited by 616
Metadata
- Authors
- James, T. D., Sandanayake, K. R. A. S., & Shinkai, S.
- Venue
- Angewandte Chemie International Edition in English
- Publisher
- Wiley
- Published
- 1994-11-17
- Volume
- 33
- Issue
- 21
- Pages
- 2207-2209
- ISSN
- 0570-0833 (ISSN-L)
- OpenAlex
- W2150423256
- Cited by
- 368
- References
- 0
- FWCI
- 10.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Glucose‐Selective Molecular Fluorescence Sensor. https://app.cochat.ai/papers/10.1002/anie.199422071
- The paper
- James, T. D., Sandanayake, K. R. A. S., & Shinkai, S. (1994). A Glucose‐Selective Molecular Fluorescence Sensor. Angewandte Chemie International Edition in English. https://doi.org/10.1002/anie.199422071
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.