Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 818

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Electronic Aptamer‐Based Sensors

Willner, Itamar, Zayats, Maya·2007·Angewandte Chemie International Edition

Abstract

The selection of aptamers—nucleic acids that specifically bind low‐molecular‐weight substrates or proteins—by the SELEX (systematic evolution of ligands by exponential enrichment) procedure has attracted recent efforts directed to the development of new specific recognition units. In particular, extensive activities have been directed to the application of aptamers as versatile materials for the design of biosensors. The Minireview summarizes the recent accomplishments in developing electronic aptamer‐based sensors (aptasensors), which include electrochemical, field‐effect transistor, and microgravimetric quartz crystal microbalance sensors, and describes methods to develop amplified aptasensor devices and label‐free aptasensors.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/anie.200604524

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 818

Metadata

Authors
Willner, I., & Zayats, M.
Venue
Angewandte Chemie International Edition
Publisher
Wiley
Published
2007-08-20
Volume
46
Issue
34
Pages
6408-6418
ISSN
  • 1433-7851 (ISSN-L)
  • 1521-3773
OpenAlex
W2098286922
Cited by
818
References
1
FWCI
19.88
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Electronic Aptamer‐Based Sensors. https://app.cochat.ai/papers/10.1002/anie.200604524
The paper
Willner, I., & Zayats, M. (2007). Electronic Aptamer‐Based Sensors. Angewandte Chemie International Edition. https://doi.org/10.1002/anie.200604524

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.