The DOI matches its Crossref record.
Fluorescent Molecular Logic Gates Using Microfluidic Devices
Abstract
Starting gate: A molecular logic gate is based on chemosensors that change their fluorescence intensity in response to various inputs (pH, metal ions) in a microfluidic system. A combinatorial circuit, such as a half adder (see picture), uses fluorescein (green) and rhodamine B (red) derivatives that respond to pH. A logic gate with a protein and Cu2+ ions as inputs is also described.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A new trend in rhodamine-based chemosensors: application of spirolactam ring-opening to sensing ions
Kim, H. N., Lee, M. H., Kim, H. J., Kim, J. S., & Yoon, J. (2008) · Chemical Society Reviews · doi:10.1039/b802497a · Cited by 1,649
Self-citationSensors for the optical detection ofcyanide ion
Xu, Z., Chen, X., Kim, H. N., & Yoon, J. (2010) · Chem. Soc. Rev. · doi:10.1039/b907368j · Cited by 1,121
Self-citationSmall steps towards the development of chemical artificial intelligent systems
Gentili, P. L. (2013) · RSC Advances · doi:10.1039/c3ra44657c · Cited by 70
Metadata
- Authors
- Kou, S., Lee, H. N., van Noort, D., Swamy, K. M. K., Kim, S. H., Soh, J. H., Lee, K., Nam, S., Yoon, J., & Park, S.
- Venue
- Angewandte Chemie International Edition
- Publisher
- Wiley
- Published
- 2008-01-11
- Volume
- 47
- Issue
- 5
- Pages
- 872-876
- ISSN
- 1433-7851 (ISSN-L)
- 1521-3773
- OpenAlex
- W2168927428
- Cited by
- 180
- References
- 0
- FWCI
- 8.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fluorescent Molecular Logic Gates Using Microfluidic Devices. https://app.cochat.ai/papers/10.1002/anie.200703813
- The paper
- Kou, S., Lee, H. N., van Noort, D., Swamy, K. M. K., Kim, S. H., Soh, J. H., Lee, K., Nam, S., Yoon, J., & Park, S. (2008). Fluorescent Molecular Logic Gates Using Microfluidic Devices. Angewandte Chemie International Edition. https://doi.org/10.1002/anie.200703813
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.