Label‐Free, Real‐Time Monitoring of Biomass Processing with Stimulated Raman Scattering Microscopy
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Label-free “chemical movies” of lignin and cellulose in fresh plant tissue were recorded during a step in the breakdown of biomass to produce biofuels by using stimulated Raman scattering microscopy. The technique allows the degradation of lignin in the cell wall to be monitored with high sensitivity, sub-micrometer spatial resolution, and high temporal resolution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Features of promising technologies for pretreatment of lignocellulosic biomass
MOSIER, N. (2005) · Bioresource Technology · doi:10.1016/j.biortech.2004.06.025 · Cited by 6,251
Cited by
Using Raman spectroscopy to characterize biological materials
Butler, H. J., Ashton, L., Bird, B., Cinque, G., Curtis, K., Dorney, J., Esmonde-White, K., Fullwood, N. J., Gardner, B., Martin-Hirsch, P. L., et al. (2016) · Nature Protocols · doi:10.1038/nprot.2016.036 · Cited by 1,309
Vibrational spectroscopic imaging of living systems: An emerging platform for biology and medicine
Cheng, J.-X., & Xie, X. S. (2015) · Science · doi:10.1126/science.aaa8870 · Cited by 874
Self-citationVideo-Rate Molecular Imaging in Vivo with Stimulated Raman Scattering
Saar, B. G., Freudiger, C. W., Reichman, J., Stanley, C. M., Holtom, G. R., & Xie, X. S. (2010) · Science · doi:10.1126/science.1197236 · Cited by 844
Self-citationHow Does Plant Cell Wall Nanoscale Architecture Correlate with Enzymatic Digestibility?
Ding, S.-Y., Liu, Y.-S., Zeng, Y., Himmel, M. E., Baker, J. O., & Bayer, E. A. (2012) · Science · doi:10.1126/science.1227491 · Cited by 738
Self-citationCoherent Nonlinear Optical Imaging: Beyond Fluorescence Microscopy
Min, W., Freudiger, C. W., Lu, S., & Xie, X. S. (2011) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.012809.103512 · Cited by 604
Self-citation
Metadata
- Authors
- Saar, B. G., Zeng, Y., Freudiger, C. W., Liu, Y., Himmel, M. E., Xie, X. S., & Ding, S.
- Venue
- Angewandte Chemie International Edition
- Publisher
- Wiley
- Published
- 2010-07-22
- Volume
- 49
- Issue
- 32
- Pages
- 5476-5479
- ISSN
- 1433-7851 (ISSN-L)
- 1521-3773
- OpenAlex
- W2169986236
- Cited by
- 106
- References
- 1
- FWCI
- 6.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Label‐Free, Real‐Time Monitoring of Biomass Processing with Stimulated Raman Scattering Microscopy. https://app.cochat.ai/papers/10.1002/anie.201000900
- The paper
- Saar, B. G., Zeng, Y., Freudiger, C. W., Liu, Y., Himmel, M. E., Xie, X. S., & Ding, S. (2010). Label‐Free, Real‐Time Monitoring of Biomass Processing with Stimulated Raman Scattering Microscopy. Angewandte Chemie International Edition. https://doi.org/10.1002/anie.201000900
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.