The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Imaging of Self‐Assembled Structures: Interpretation of TEM and Cryo‐TEM Images
Open accessAbstract
The investigation of solution‐borne nanostructures by transmission electron microscopy (TEM) is a frequently used analytical method in materials chemistry. In many cases, the preparation of the TEM sample involves drying and staining steps, and the collection of images leads to the interaction of the specimen with the electron beam. Both aspects call for cautious interpretation of the resulting electron micrographs. Alternatively, a near‐native solvated state can be preserved by cryogenic vitrification and subsequent imaging by low‐dose cryogenic TEM. In this Minireview, we provide a critical analysis of sample preparation, and more importantly, of the acquisition and interpretation of electron micrographs. This overview should provide a framework for the application of (cryo)‐TEM as a powerful and reliable tool for the analysis of colloidal and self‐assembled structures with nanoscopic dimensions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cui, H., Hodgdon, T. K., Kaler, E. W., Abezgauz, L., Danino, D., Lubovsky, M., Talmon, Y., & Pochan, D. J. (2007) · Soft Matter · doi:10.1039/b704194b · Cited by 208
The First Account of a Structurally Persistent Micelle
Kellermann, M., Bauer, W., Hirsch, A., Schade, B., Ludwig, K., & Böttcher, C. (2004) · Angewandte Chemie International Edition · doi:10.1002/anie.200353510 · Cited by 165
Cryoelectron microscopy of liposomes
Frederik, P. M., & Hubert, D. H. W. (2005) · Methods in Enzymology · doi:10.1016/s0076-6879(05)91024-0 · Cited by 121
Self-citation
Cited by
Pre-nucleation clusters as solute precursors in crystallisation
Gebauer, D., Kellermeier, M., Gale, J. D., Bergström, L., & Cölfen, H. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60451a · Cited by 1,015
Prenucleation clusters and non-classical nucleation
Gebauer, D., & Cölfen, H. (2011) · Nano Today · doi:10.1016/j.nantod.2011.10.005 · Cited by 682
Recent advances in catalysis in micellar media
La Sorella, G., Strukul, G., & Scarso, A. (2015) · Green Chemistry · doi:10.1039/c4gc01368a · Cited by 595
Lipshutz, B. H., Ghorai, S., Abela, A. R., Moser, R., Nishikata, T., Duplais, C., Krasovskiy, A., Gaston, R. D., & Gadwood, R. C. (2011) · The Journal of Organic Chemistry · doi:10.1021/jo101974u · Cited by 499
Adaptive Supramolecular Nanomaterials Based on Strong Noncovalent Interactions
Rybtchinski, B. (2011) · ACS Nano · doi:10.1021/nn2025397 · Cited by 461
Metadata
- Authors
- Friedrich, H., Frederik, P. M., de With, G., & Sommerdijk, N. A. J. M.
- Venue
- Angewandte Chemie International Edition
- Publisher
- Wiley
- Published
- 2010-09-06
- Volume
- 49
- Issue
- 43
- Pages
- 7850-7858
- ISSN
- 1433-7851 (ISSN-L)
- 1521-3773
- OpenAlex
- W2101826732
- Cited by
- 235
- References
- 3
- FWCI
- 9.89
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.