The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Super‐Resolution Imaging of the Golgi in Live Cells with a Bioorthogonal Ceramide Probe
Open accessAbstract
We report a lipid‐based strategy to visualize Golgi structure and dynamics at super‐resolution in live cells. The method is based on two novel reagents: a trans‐cyclooctene‐containing ceramide lipid (Cer‐TCO) and a highly reactive, tetrazine‐tagged near‐IR dye (SiR‐Tz). These reagents assemble via an extremely rapid “tetrazine‐click” reaction into Cer‐SiR, a highly photostable “vital dye” that enables prolonged live‐cell imaging of the Golgi apparatus by 3D confocal and STED microscopy. Cer‐SiR is nontoxic at concentrations as high as 2 μ M and does not perturb the mobility of Golgi‐resident enzymes or the traffic of cargo from the endoplasmic reticulum through the Golgi and to the plasma membrane.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
NIH Image to ImageJ: 25 years of image analysis
Schneider, C. A., Rasband, W. S., & Eliceiri, K. W. (2012) · Nature Methods · doi:10.1038/nmeth.2089 · Cited by 64,638
Hell, S. W. (2007) · Science · doi:10.1126/science.1137395 · Cited by 2,967
Super-resolution fluorescence microscopy
Huang, B., Bates, M., & Zhuang, X. (2009) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.77.061906.092014 · Cited by 1,657
Cited by
Fluorescence nanoscopy in cell biology
Sahl, S. J., Hell, S. W., & Jakobs, S. (2017) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm.2017.71 · Cited by 990
Bioorthogonal Chemistry and Its Applications
Bird, R. E., Lemmel, S. A., Yu, X., & Zhou, Q. A. (2021) · Bioconjugate Chemistry · doi:10.1021/acs.bioconjchem.1c00461 · Cited by 409
Switchable Fluorophores for Single-Molecule Localization Microscopy
Li, H., & Vaughan, J. C. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00767 · Cited by 319
SiR–Hoechst is a far-red DNA stain for live-cell nanoscopy
Lukinavičius, G., Blaukopf, C., Pershagen, E., Schena, A., Reymond, L., Derivery, E., Gonzalez-Gaitan, M., D’Este, E., Hell, S. W., Wolfram Gerlich, D., et al. (2015) · Nature Communications · doi:10.1038/ncomms9497 · Cited by 294
Metadata
- Authors
- Erdmann, R. S., Takakura, H., Thompson, A. D., Rivera‐Molina, F., Allgeyer, E. S., Bewersdorf, J., Toomre, D., & Schepartz, A.
- Venue
- Angewandte Chemie International Edition
- Publisher
- Wiley
- Published
- 2014-07-31
- Volume
- 53
- Issue
- 38
- Pages
- 10242-10246
- ISSN
- 1433-7851 (ISSN-L)
- 1521-3773
- OpenAlex
- W2096156293
- Cited by
- 164
- References
- 3
- FWCI
- 8.13
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Super‐Resolution Imaging of the Golgi in Live Cells with a Bioorthogonal Ceramide Probe. https://app.cochat.ai/papers/10.1002/anie.201403349
- The paper
- Erdmann, R. S., Takakura, H., Thompson, A. D., Rivera‐Molina, F., Allgeyer, E. S., Bewersdorf, J., Toomre, D., & Schepartz, A. (2014). Super‐Resolution Imaging of the Golgi in Live Cells with a Bioorthogonal Ceramide Probe. Angewandte Chemie International Edition. https://doi.org/10.1002/anie.201403349
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.