Using Ambient Ion Beams to Write Nanostructured Patterns for Surface Enhanced Raman Spectroscopy
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Electrolytic spray deposition was used to pattern surfaces with 2D metallic nanostructures. Spots that contain silver nanoparticles (AgNP) were created by landing solvated silver ions at desired locations using electrically floated masks to focus the metal ions to an area as little as 20 μm in diameter. The AgNPs formed are unprotected and their aggregates can be used for surface‐enhanced Raman spectroscopy (SERS). The morphology and SERS activity of the NP structures were controlled by the surface coverage of landed silver ions. The NP structures created could be used as substrates onto which SERS samples were deposited or prepared directly on top of predeposited samples of interest. The evenly distributed hot spots in the micron‐sized aggregates had an average SERS enhancement factor of 10 8. The surfaces showed SERS activity when using lasers of different wavelengths (532, 633, and 785 nm) and were stable in air.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Surface raman spectroelectrochemistry
Jeanmaire, D. L., & Van Duyne, R. P. (1977) · Journal of Electroanalytical Chemistry and Interfacial Electrochemistry · doi:10.1016/s0022-0728(77)80224-6 · Cited by 4,738
Shell-isolated nanoparticle-enhanced Raman spectroscopy
Li, J. F., Huang, Y. F., Ding, Y., Yang, Z. L., Li, S. B., Zhou, X. S., Fan, F. R., Zhang, W., Zhou, Z. Y., Wu, D. Y., et al. (2010) · Nature · doi:10.1038/nature08907 · Cited by 3,559
Cited by
Well-Defined Materials for Heterogeneous Catalysis: From Nanoparticles to Isolated Single-Atom Sites
Li, Z., Ji, S., Liu, Y., Cao, X., Tian, S., Chen, Y., Niu, Z., & Li, Y. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00311 · Cited by 1,245
Catalysis by clusters with precise numbers of atoms
Tyo, E. C., & Vajda, S. (2015) · Nature Nanotechnology · doi:10.1038/nnano.2015.140 · Cited by 729
Accelerated Reaction Kinetics in Microdroplets: Overview and Recent Developments
Wei, Z., Li, Y., Cooks, R. G., & Yan, X. (2020) · Annual Review of Physical Chemistry · doi:10.1146/annurev-physchem-121319-110654 · Cited by 631
“By electrospraying metal ions through a partially masked plate, one can generate two-dimensional (2D)-patterned nanoparticle structures (116).”
BackgroundSelf-citationOrganic Reactions in Microdroplets: Reaction Acceleration Revealed by Mass Spectrometry
Yan, X., Bain, R. M., & Cooks, R. G. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201602270 · Cited by 583
Self-citationSynthetic strategies of supported atomic clusters for heterogeneous catalysis
Rong, H., Ji, S., Zhang, J., Wang, D., & Li, Y. (2020) · Nature Communications · doi:10.1038/s41467-020-19571-6 · Cited by 367
Metadata
- Authors
- Li, A., Baird, Z., Bag, S., Sarkar, D., Prabhath, A., Pradeep, T., & Cooks, R. G.
- Venue
- Angewandte Chemie International Edition
- Publisher
- Wiley
- Published
- 2014-09-04
- Volume
- 53
- Issue
- 46
- Pages
- 12528-12531
- ISSN
- 1433-7851 (ISSN-L)
- 1521-3773
- OpenAlex
- W2165975545
- Cited by
- 76
- References
- 2
- FWCI
- 2.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.