The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Ultrathin Cell‐Membrane‐Mimic Phosphorylcholine Polymer Film Coating Enables Large Improvements for In Vivo Electrochemical Detection
Abstract
Resisting biomolecule adsorption onto the surface of brain‐implanted microelectrodes is a key issue for in vivo monitoring of neurochemicals. Herein, we demonstrate that an ultrathin cell‐membrane‐mimic film of ethylenedioxythiophene tailored with zwitterionic phosphorylcholine (EDOT‐PC) electropolymerized onto the surface of a carbon fiber microelectrode (CFE) not only resists protein adsorption but also maintains the sensitivity and time response for in vivo monitoring of dopamine (DA). As a consequence, the as‐prepared PEDOT‐PC/CFEs could be used as a new reliable platform for tracking DA in vivo and would help understand the physiological and pathological functions of DA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomaterials: Where We Have Been and Where We Are Going
Ratner, B. D., & Bryant, S. J. (2004) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140027 · Cited by 1,507
In-Vivo Electrochemistry: What Can We Learn about Living Systems?
Wilson, G. S., & Johnson, M. A. (2008) · Chemical Reviews · doi:10.1021/cr068082i · Cited by 178
Cited by
Maduraiveeran, G., Sasidharan, M., & Ganesan, V. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.12.031 · Cited by 912
Li, Q., Wen, C., Yang, J., Zhou, X., Zhu, Y., Zheng, J., Cheng, G., Bai, J., Xu, T., Ji, J., et al. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00344 · Cited by 790
Antifouling Strategies for Selective In Vitro and In Vivo Sensing
Jiang, C., Wang, G., Hein, R., Liu, N., Luo, X., & Davis, J. J. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00739 · Cited by 598
Fundamentals of fast-scan cyclic voltammetry for dopamine detection
Venton, B. J., & Cao, Q. (2020) · The Analyst · doi:10.1039/c9an01586h · Cited by 357
Achievements and Challenges for Real-Time Sensing of Analytes in Sweat within Wearable Platforms
Brothers, M. C., DeBrosse, M., Grigsby, C. C., Naik, R. R., Hussain, S. M., Heikenfeld, J., & Kim, S. S. (2019) · Accounts of Chemical Research · doi:10.1021/acs.accounts.8b00555 · Cited by 207
Metadata
- Authors
- Liu, X., Xiao, T., Wu, F., Shen, M., Zhang, M., Yu, H., & Mao, L.
- Venue
- Angewandte Chemie International Edition
- Publisher
- Wiley
- Published
- 2017-08-21
- Volume
- 56
- Issue
- 39
- Pages
- 11802-11806
- ISSN
- 1433-7851 (ISSN-L)
- 1521-3773
- OpenAlex
- W2744517544
- Cited by
- 158
- References
- 2
- FWCI
- 7.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultrathin Cell‐Membrane‐Mimic Phosphorylcholine Polymer Film Coating Enables Large Improvements for In Vivo Electrochemical Detection. https://app.cochat.ai/papers/10.1002/anie.201705900
- The paper
- Liu, X., Xiao, T., Wu, F., Shen, M., Zhang, M., Yu, H., & Mao, L. (2017). Ultrathin Cell‐Membrane‐Mimic Phosphorylcholine Polymer Film Coating Enables Large Improvements for In Vivo Electrochemical Detection. Angewandte Chemie International Edition. https://doi.org/10.1002/anie.201705900
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.