The DOI matches its Crossref record; 81 of the 81 references it cites were found in a registry or an index.
Fundamentals of fast-scan cyclic voltammetry for dopamine detection
Open accessAbstract
Fast-scan cyclic voltammetry (FSCV) is used with carbon-fiber microelectrodes for the real-time detection of neurotransmitters on the subsecond time scale.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrochemical Methods: Fundamentals and Applications
Bard, A. J., & Faulkner, L. R. (1980) · Cited by 22,435
Electrochemical Methods: Fundamentals and Applications
de Rooij, D. M. R. (2003) · Anti-Corrosion Methods and Materials · doi:10.1108/acmm.2003.12850eae.001 · Cited by 13,009
A practical beginner’s guide to cyclic voltammetry
Elgrishi, N., Rountree, K. J., McCarthy, B. D., Rountree, E. S., Eisenhart, T. T., & Dempsey, J. L. (2018) · Journal of Chemical Education · doi:10.1021/acs.jchemed.7b00361 · Cited by 4,263
Advanced Carbon Electrode Materials for Molecular Electrochemistry
McCreery, R. L. (2008) · Chemical Reviews · doi:10.1021/cr068076m · Cited by 2,729
Subsecond dopamine release promotes cocaine seeking
Phillips, P. E. M., Stuber, G. D., Heien, M. L. A. V., Wightman, R. M., & Carelli, R. M. (2003) · Nature · doi:10.1038/nature01476 · Cited by 1,113
Monitoring Rapid Chemical Communication in the Brain
Robinson, D. L., Hermans, A., Seipel, A. T., & Wightman, R. M. (2008) · Chemical Reviews · doi:10.1021/cr068081q · Cited by 669
Detecting Subsecond Dopamine Release with Fast-Scan Cyclic Voltammetry in Vivo
Robinson, D. L., Venton, B. J., Heien, M. L. A. V., & Wightman, R. M. (2003) · Clinical Chemistry · doi:10.1373/49.10.1763 · Cited by 606
Self-citationRecent trends in carbon nanomaterial-based electrochemical sensors for biomolecules: A review
Yang, C., Denno, M. E., Pyakurel, P., & Venton, B. J. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.05.049 · Cited by 577
Self-citationWightman, R. M. (1981) · Analytical Chemistry · doi:10.1021/ac00232a004 · Cited by 544
Characterization of electrochemically pretreated glassy carbon electrodes
Engstrom, R. C., & Strasser, V. A. (1984) · Analytical Chemistry · doi:10.1021/ac00266a005 · Cited by 427
Cited by
Locus coeruleus: a new look at the blue spot
Poe, G. R., Foote, S., Eschenko, O., Johansen, J. P., Bouret, S., Aston-Jones, G., Harley, C. W., Manahan-Vaughan, D., Weinshenker, D., Valentino, R., et al. (2020) · Nature Reviews Neuroscience · doi:10.1038/s41583-020-0360-9 · Cited by 720
Imaging neurotransmitter and neuromodulator dynamics in vivo with genetically encoded indicators
Sabatini, B. L., & Tian, L. (2020) · Neuron · doi:10.1016/j.neuron.2020.09.036 · Cited by 203
Metadata
- Authors
- Venton, B. J., & Cao, Q.
- Venue
- The Analyst
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2020
- Volume
- 145
- Issue
- 4
- Pages
- 1158-1168
- ISSN
- 0003-2654 (ISSN-L)
- 1364-5528
- OpenAlex
- W2997325579
- Cited by
- 357
- References
- 81
- FWCI
- 10.49
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fundamentals of fast-scan cyclic voltammetry for dopamine detection. https://app.cochat.ai/papers/10.1039/c9an01586h
- The paper
- Venton, B. J., & Cao, Q. (2020). Fundamentals of fast-scan cyclic voltammetry for dopamine detection. The Analyst. https://doi.org/10.1039/c9an01586h
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.