Anisotropic Boron–Carbon Hetero‐Nanosheets for Ultrahigh Energy Density Supercapacitors
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A 2D boron nanosheet that exhibits high theoretical capacitance, around four times that of graphene, is a significant supercapacitor electrode. However, its bulk structure with low interlaminar conduction and porosity restricts the charge transfer, ion diffusion, and energy density. Herein, we develop a new 2D hetero‐nanosheet made of anisotropic boron–carbon nanosheets (ABCNs) by B−C chemical bonds via gas‐phase exfoliation and condensation bottom‐up strategy. The ABCNs are constructed into high flexible supercapacitor electrode by microfluidic electrospinning. The ABCN electrode greatly promotes smooth migration and excessive storage of electrolyte ions due to large interlayer conductivity, ionic pathways, and accessible surfaces. The flexible supercapacitor delivers ultrahigh volumetric energy density of 167.05 mWh cm −3 and capacitance of 534.5 F cm −3 . A wearable energy‐sensor system is designed to stably monitor physiological signals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Textile-like electrodes made of 2D heterostructures have also led to innovative supercapacitors with a maximum energy density of 167.05 mWh cm–3 and excellent cycling stability.”
From End-to-end design of wearable sensors (2022) · cites this paper as [213]
In the citing paper
“Using these textile-like electrodes, a wearable energy-sensor system has been shown to monitor physiological signals in real time, including wrist pulse, heartbeat and body-bending signals213.”
From End-to-end design of wearable sensors (2022) · cites this paper as [213]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
U1 snRNP regulates cancer cell migration and invasion in vitro
Oh, J.-M., Venters, C. C., Di, C., Pinto, A. M., Wan, L., Younis, I., Cai, Z., Arai, C., So, B. R., Duan, J., et al. (2020) · Nature Communications · doi:10.1038/s41467-019-13993-7 · Cited by 7,157
Research works printed but not linked: 71
- 10.1126/science.1182383 · DOI · Paper page
- 10.1126/science.1216744 · DOI · Paper page
- 10.1021/jacs.8b06460 · DOI · Paper page
- 10.1021/acsnano.7b02767 · DOI
- 10.1038/nature07719 · DOI · Paper page
- 10.1038/ncomms13319 · DOI · Paper page
- 10.1038/ncomms4754 · DOI · Paper page
- 10.1002/anie.201908985 · DOI · Paper page
- 10.1002/ange.201908985 · DOI
- 10.1002/anie.201905713 · doi:10.1002/anie.201905713
- 10.1002/ange.201905713 · doi:10.1002/ange.201905713
- Ma H., 2020, Angew. Chem. Int. Ed.
- Zou L., 2020, Angew. Chem. Int. Ed.
- Simon P., 2020, Nat. Mater.
- 10.1038/s41467-017-02152-5 · DOI
- 10.1126/science.aam5852 · DOI · Paper page
- 10.1002/adma.201505730 · DOI · Paper page
- 10.1126/science.aag2421 · DOI · Paper page
- 10.1038/nnano.2015.40 · DOI · Paper page
- 10.1039/C6CS00424E · DOI · Paper page
- 10.1002/advs.201500023 · DOI
- 10.1021/cr300356t · DOI · Paper page
- 10.1021/acs.nanolett.6b00070 · DOI · Paper page
- 10.1038/nature07736 · DOI · Paper page
- 10.1021/acsenergylett.6b00483 · DOI
- 10.1021/acsnano.7b07444 · DOI · Paper page
- 10.1002/aenm.201703117 · doi:10.1002/aenm.201703117
- 10.1038/s41586-018-0205-0 · DOI · Paper page
- 10.1038/nenergy.2017.89 · DOI · Paper page
- 10.1039/C8TA02124D · DOI
- 10.1002/smll.201701314 · DOI · Paper page
- 10.1016/j.carbon.2017.09.084 · DOI
- 10.1002/anie.201605515 · DOI · Paper page
- 10.1002/ange.201605515 · DOI
- Wang T., 2020, Nanoscale, 12
- 10.1016/j.nanoen.2020.104734 · DOI · Paper page
- 10.1002/anie.201203207 · DOI · Paper page
- 10.1002/ange.201203207 · DOI
- 10.1038/srep02771 · DOI · Paper page
- 10.1080/14786430902984566 · doi:10.1080/14786430902984566
- 10.1002/adfm.201606219 · DOI
- 10.1021/acs.nanolett.9b01511 · DOI
- 10.1021/nl0498785 · DOI · Paper page
- 10.1039/c1jm12620b · DOI · Paper page
- 10.1039/b311390f · DOI · Paper page
- 10.1021/acsami.9b21157 · DOI
- 10.1002/aenm.201903724 · DOI
- 10.1038/ncomms8258 · DOI · Paper page
- 10.1155/JNM/2006/58237 · doi:10.1155/jnm/2006/58237
- Weber W., 1975, Solid State Commun., 36, 967
- 10.1016/j.joule.2018.06.007 · DOI · Paper page
- 10.1039/C7TA11135E · DOI
- Chen S., 2019, Angew. Chem. Int. Ed., 58, 13564
- 10.1002/ange.201907464 · doi:10.1002/ange.201907464
- 10.1021/acs.chemrev.8b00593 · DOI · Paper page
- 10.1002/advs.201901931 · DOI
- 10.1021/acsami.6b01872 · DOI
- 10.1002/adma.201705710 · doi:10.1002/adma.201705710
- 10.1038/nnano.2014.93 · DOI · Paper page
- 10.1038/s41467-018-06914-7 · doi:10.1038/s41467-018-06914-7
- 10.1002/adma.201806492 · DOI · Paper page
- 10.1002/anie.201911023 · DOI
- 10.1002/ange.201911023 · doi:10.1002/ange.201911023
- 10.1002/anie.202000951 · DOI
- 10.1002/ange.202000951 · DOI
- 10.1002/adfm.201702493 · DOI · Paper page
- 10.1021/acsnano.9b08952 · DOI · Paper page
- 10.1039/C7TB01760J · DOI
- 10.1038/ncomms8260 · DOI · Paper page
- 10.1002/adfm.201703808 · DOI
- 10.1039/c2ee23442d · DOI · Paper page
Cited by
End-to-end design of wearable sensors
Ates, H. C., Nguyen, P. Q., Gonzalez-Macia, L., Morales-Narváez, E., Güder, F., Collins, J. J., & Dincer, C. (2022) · Nature Reviews Materials · doi:10.1038/s41578-022-00460-x · Cited by 1,306
Dong, W., Xie, M., Zhao, S., Qin, Q., & Huang, F. (2023) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2022.100713 · Cited by 319
Saad, A., Liu, D., Wu, Y., Song, Z., Li, Y., Najam, T., Zong, K., Tsiakaras, P., & Cai, X. (2021) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2021.120529 · Cited by 241
Xu, H., Hu, R., Zhang, Y., Yan, H., Zhu, Q., Shang, J., Yang, S., & Li, B. (2021) · Energy Storage Materials · doi:10.1016/j.ensm.2021.09.003 · Cited by 158
Metadata
- Authors
- Wu, T., Wu, X., Li, L., Hao, M., Wu, G., Zhang, T., & Chen, S.
- Affiliations
- State Key Laboratory of Materials-Oriented Chemical Engineering College of Chemical Engineering Jiangsu Key Laboratory of Fine Chemicals and Functional Polymer Materials Nanjing Tech University (former: Nanjing University of Technology) Nanjing 210009 P. R. China
- i-lab, Key Laboratory of multifunctional nanomaterials and smart systems Suzhou Institute of Nano-Tech and Nano-Bionics (SINANO) Chinese Academy of Science (CAS) Suzhou 215123 P. R. China
- ORCID
- Chen, Su
- Venue
- Angewandte Chemie International Edition
- Publisher
- Wiley
- Published
- 2020-10-23
- Volume
- 59
- Issue
- 52
- Pages
- 23800-23809
- ISSN
- 1433-7851
- 1521-3773
- Cited by
- 94
- References
- 1
- Language
- en
- Funders
- National Natural Science Foundation of China (21736006, 21706120)
- Natural Science Foundation of Jiangsu Province (BK20170973)
- National Basic Research Program of China (2016YFB0401700)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.