Loss and transformation products of the aromatic antioxidants in MDPE film under long‐term exposure to biotic and abiotic conditions
The DOI matches its Crossref record.
Abstract
The loss of a primary phenolic antioxidant Irganox 1010 and of a secondary phosphite antioxidant Irgafos 168 from a medium density polyethylene film (MDPE) was investigated after exposure of the film for 4 years to different environments such as aqueous media at pH5 and 7, open air, and compost, with an exposure of exposition of 25°C. An ultrasonic extraction technique using chloroform as extraction solvent was applied to recover the residual antioxidants from the polymeric matrix, and this was followed by High‐Performance Liquid Chromatography (HPLC) with acetonitrile as mobile phase and a quantitative analysis at a wavelength of 280 nm of the extracted antioxidants. The amount of antioxidant lost varied remarkably depending on the testing medium. The fastest loss of antioxidant was found on exposure to open air and sunlight while the slowest loss was observed in compost. Thermo‐analytical measurements were made to characterize the residual thermo‐oxidative stability of MDPE film in terms of oxidation temperature and oxidation induction time, to provide a greater insight into the underlying mechanisms of ageing in the different environments. Analysis by Gas chromatography–Mass Spectrometry (GC‐MS) revealed that degradation of the polymeric matrix resulted in the formation of hydrocarbons and oxygen‐containing compounds such as alcohols, carboxylic acids, aldehydes, and esters. The transformation products of the antioxidants formed as result of processing or exposure to the tested media were also identified. The transformation of the phenoxy radical of the Irganox 1010 produced the ester, acid, dealkylated cinnamate, and quinone products, whereas Irgafos 168 yielded oxidation products and the phenolic hydrolysis byproduct 2,4‐di‐tert‐butylphenol. © 2002 Wiley Periodicals, Inc. J Appl Polym Sci 85: 974–988, 2002
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ageing of HDPE geomembrane exposed to air, water and leachate at different temperatures☆
Rowe, R. K., Rimal, S., & Sangam, H. (2009) · Geotextiles and Geomembranes · doi:10.1016/j.geotexmem.2008.09.007 · Cited by 221
Brocks, J. J., Grosjean, E., & Logan, G. A. (2008) · Geochimica et Cosmochimica Acta · doi:10.1016/j.gca.2007.11.028 · Cited by 124
Extractables/leachables from plastic tubing used in product manufacturing
Jenke, D. R., Story, J., & Lalani, R. (2006) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2006.02.011 · Cited by 52
Organic residues in archaeology: the highs and lows of recent research
Steele, V. (2013) · ACS Symposium Series · doi:10.1021/bk-2013-1147.ch005 · Cited by 21
Metadata
- Authors
- Haider, N., & Karlsson, S.
- Venue
- Journal of Applied Polymer Science
- Publisher
- Wiley
- Published
- 2002-05-21
- Volume
- 85
- Issue
- 5
- Pages
- 974-988
- ISSN
- 0021-8995 (ISSN-L)
- 1097-4628
- OpenAlex
- W2137010094
- Cited by
- 51
- References
- 0
- FWCI
- 1.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.