The DOI matches its Crossref record.
Dynamic swelling behavior of pH‐sensitive anionic hydrogels used for protein delivery
Abstract
There have been many attempts to use anionic hydrogels as oral protein delivery carriers because of their pH‐responsive swelling behavior. The dynamic swelling behavior of poly(methacrylic acid‐co‐methacryloxyethyl glucoside) and poly(methacrylic acid‐g‐ethylene glycol) hydrogels was investigated to determine the mechanism of water transport through these anionic hydrogels. The exponential relation Mt/M∞ = ktn (where Mt is the mass of water absorbed at time t and M∞ is the mass of water absorbed at equilibrium) was used to calculate the exponent (n) describing the Fickian or non‐Fickian behavior of swelling polymer networks. The mechanism of water transport through these gels was significantly affected by the pH of the swelling medium. The mechanism of water transport became more relaxation‐controlled in a swelling medium of pH 7.0, which was higher than p Ka of the gels. The experimental results of the time‐dependent swelling behaviors of the gels were analyzed with several mathematical models. © 2003 Wiley Periodicals, Inc. J Appl Polym Sci 89: 1606–1613, 2003
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Thermo- and pH-responsive polymers in drug delivery☆
SCHMALJOHANN, D. (2006) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2006.09.020 · Cited by 3,023
Hydrogels in controlled release formulations: Network design and mathematical modeling
Lin, C.-C., & Metters, A. T. (2006) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2006.09.004 · Cited by 1,768
Biomaterials: Where We Have Been and Where We Are Going
Ratner, B. D., & Bryant, S. J. (2004) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140027 · Cited by 1,507
Responsive polymers in controlled drug delivery
Bajpai, A. K., Shukla, S. K., Bhanu, S., & Kankane, S. (2008) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2008.07.005 · Cited by 1,391
Therapeutic applications of hydrogels in oral drug delivery
Sharpe, L. A., Daily, A. M., Horava, S. D., & Peppas, N. A. (2014) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.2014.902047 · Cited by 354
Self-citation
Metadata
- Authors
- Kim, B., La Flamme, K., & Peppas, N. A.
- Venue
- Journal of Applied Polymer Science
- Publisher
- Wiley
- Published
- 2003-05-23
- Volume
- 89
- Issue
- 6
- Pages
- 1606-1613
- ISSN
- 0021-8995 (ISSN-L)
- 1097-4628
- OpenAlex
- W2131024128
- Cited by
- 270
- References
- 0
- FWCI
- 5.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dynamic swelling behavior of pH‐sensitive anionic hydrogels used for protein delivery. https://app.cochat.ai/papers/10.1002/app.12337
- The paper
- Kim, B., La Flamme, K., & Peppas, N. A. (2003). Dynamic swelling behavior of pH‐sensitive anionic hydrogels used for protein delivery. Journal of Applied Polymer Science. https://doi.org/10.1002/app.12337
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.