Characterization of the water state of hyaluronic acid and poly(vinyl alcohol) interpenetrating polymer networks
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Interpenetrating polymer networks (IPNs) composed of hyaluronic acid and poly(vinyl alcohol) hydrogels were prepared, and the influence of water and the drying kinetics were investigated. The IPN hydrogels were characterized with thermogravimetric analysis (TGA) and differential scanning calorimetry (DSC). The glass‐transition temperatures of the IPN hydrogels decreased with increasing water content. The bound water was the sum of the nonfreezing bound water and freezing bound water. From the DSC melting curves, the values of the total water and freezing bound water were evaluated for IPN hydrogels containing large amounts of water. At the same time, the bound water value was estimated with TGA. In the TGA curves, one‐step and two‐step weight losses, corresponding to free water and nonfreezing bound water, were observed. The bound water of the hydrophilic polymers broke the hydrogen bonding between the hydroxyl groups of the polymers. The swollen IPN hydrogels exhibited relatively high bound water contents (43.04–59.17%) by DSC and TGA. The bound water contents of the dry IPN hydrogel films were 10.2–15.29% by TGA. The drying reaction rate constant of the IPN hydrogel increased with increasing temperature. © 2004 Wiley Periodicals, Inc. J Appl Polym Sci 92: 1467–1472, 2004
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dai, W. S., & Barbari, T. A. (1999) · Journal of Membrane Science · doi:10.1016/s0376-7388(98)00330-5 · Cited by 142
Cited by
Design and applications of interpenetrating polymer network hydrogels. A review
Dragan, E. S. (2014) · Chemical Engineering Journal · doi:10.1016/j.cej.2014.01.065 · Cited by 992
Solubility of Carbohydrates in Ionic Liquids
Zakrzewska, M. E., Bogel-Łukasik, E., & Bogel-Łukasik, R. (2010) · Energy & Fuels · doi:10.1021/ef901215m · Cited by 490
Pore structure in supermacroporous polyacrylamide based cryogels
Plieva, F. M., Karlsson, M., Aguilar, M.-R., Gomez, D., Mikhalovsky, S., & Galaev’, I. Y. (2005) · Soft Matter · doi:10.1039/b510010k · Cited by 257
Luo, C., Guo, A., Zhao, Y., & Sun, X. (2022) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2022.119268 · Cited by 173
Physical properties of PLGA films during polymer degradation
Houchin, M. L., & Topp, E. M. (2009) · Journal of Applied Polymer Science · doi:10.1002/app.30813 · Cited by 133
Metadata
- Authors
- Kim, S. J., Lee, C. K., & Kim, S. I.
- Venue
- Journal of Applied Polymer Science
- Publisher
- Wiley
- Published
- 2004-02-26
- Volume
- 92
- Issue
- 3
- Pages
- 1467-1472
- ISSN
- 0021-8995 (ISSN-L)
- 1097-4628
- OpenAlex
- W2039256191
- Cited by
- 59
- References
- 1
- FWCI
- 1.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.