CoChat

A one‐step method for fabricating chitosan microspheres

Kuo, Shyh Ming, Niu, Gregory Cheng‐Chie, Chang, Shwu Jen, Kuo, Chia Hung, Bair, Miin Shyan · 2004 · Journal of Applied Polymer Science
Cited by 44

The DOI matches its Crossref record.

Abstract

A simple and in situ method, by using a high‐voltage electrostatic system, for the fabrication of chitosan microspheres (in a form of isolatable microgels) by an extrusion process, exhibiting variable sizes and different membrane structures, was presented. The chitosan microspheres exhibited good sphericity and were in the range of 185.8 ± 13.8 to 380.9 ± 11.5 μm in diameter. There were two significant factors, the pump flow rate and electrostatic field strength, that affected the chitosan microsphere size. The microsphere size decreased when the flow rate was increased from 0.1 to 0.4 mL/h. Also, the microsphere size decreased when the electrostatic field strength was increased from 5.5 to 6.5 kV/cm. However, when the electrostatic field strength was raised to 7 kV/cm and higher, the microsphere size increased. For the latter case, with other parameters fixed, chitosan microsphere size can be controlled by adjusting the electrostatic field strength and predetermined by a simple linear regression equation: Microsphere Diameter (D, in μm) = −(75.48) + 45.67 × (Electrostatic Field Strength, E, in kV/cm), at [7 ≤ (Electrostatic Field Strength) ≤ 10] (R2 = 0.956, P < 0.001). Following treatment with various ratios of crosslinking/gelating (Na 5 P 3 O 10/NaOH) agents, the prepared chitosan microspheres exhibited distinct membrane structures that yielded various mechanical strengths. In the Na 5 P 3 O 10/NaOH ratio of 19, the chitosan microspheres had a distinct two‐layer structure. The selection of crosslinking/gelating ratio provided an additional degree of freedom, permitting the simultaneous regulation of mechanical properties and permeability of the microspheres, without extra manipulation, and thus, improved applicability in the biomedical field. When the chitosan microsphere extrusion process was used to encapsulate β‐tricalcium phosphate powder for application as bony material, we found that the ultra fine β‐tricalcium phosphate powder was trapped inside of the membrane very well. After appropriate collecting procedures, stored microspheres also retained good spherical shape. © 2004 Wiley Periodicals, Inc. J Appl Polym Sci 94: 2150–2157, 2004

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/app.21131

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Kuo, S. M., Niu, G. C., Chang, S. J., Kuo, C. H., & Bair, M. S.
Venue
Journal of Applied Polymer Science
Publisher
Wiley
Published
2004-10
Volume
94
Issue
5
Pages
2150-2157
ISSN
  • 0021-8995 (ISSN-L)
  • 1097-4628
OpenAlex
W2122867186
Cited by
44
References
0
FWCI
3.27
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.