The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Characterization of polyvinyl alcohol/gelatin blend hydrogel films for biomedical applications
Abstract
In the present investigation, attempt was made to prepare blend hydrogel by esterification of polyvinyl alcohol with gelatin. The blend hydrogel was further converted into films by the conventional solution‐casting method. These films were characterized by FTIR, DSC, and X‐ray diffraction studies. The refractive index and viscosity of different composition of the blends were measured in the solution phase of the material. The mechanical properties of the blend films were measured by tensile test. Swelling behavior of the blend hydrogel was also studied. The FTIR spectrum of the blend film indicated complete esterification of the free carboxylic group of gelatin. The DSC results indicate that the addition of gelatin with PVA changes the thermal behavior like melting temperature of PVA, which may be due to the miscibility of PVA with gelatin. The interaction of gelatin with PVA molecule changes the crystallite parameters and the degree of crystallinity. The crystallinity of the blend film was mainly due to gelatin. The comparison of viscosity indicated an increase in the segment density within the molecular coil. The results revealed the changes observed in the properties of the gel, and it enhances the gel formation at viscoelastic phase of the material. The blend film had sufficient strength and water‐holding capacity. The results obtained indicated that the blend film could be used for various biomedical applications such as wound dressing and drug‐delivery systems. © 2008 Wiley Periodicals, Inc. J Appl Polym Sci, 2008
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hydrogels for biomedical applications
Hoffman, A. S. (2002) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(01)00239-3 · Cited by 4,864
Biomaterial biocompatibility and the macrophage
Anderson, J. M., & Miller, K. M. (1984) · Biomaterials · doi:10.1016/0142-9612(84)90060-7 · Cited by 403
Cited by
Compatibilization in bio-based and biodegradable polymer blends
Imre, B., & Pukánszky, B. (2013) · European Polymer Journal · doi:10.1016/j.eurpolymj.2013.01.019 · Cited by 613
Layered double hydroxide films: synthesis, properties and applications
Guo, X., Zhang, F., Evans, D. G., & Duan, X. (2010) · Chemical Communications · doi:10.1039/c0cc00313a · Cited by 461
Recent advances in mechanical properties of biopolymer composites: a review
Sadasivuni, K. K., Saha, P., Adhikari, J., Deshmukh, K., Ahamed, M. B., & Cabibihan, J. (2020) · Polymer Composites · doi:10.1002/pc.25356 · Cited by 294
Self-citationHaghighi, H., Gullo, M., La China, S., Pfeifer, F., Siesler, H. W., Licciardello, F., & Pulvirenti, A. (2021) · Food Hydrocolloids · doi:10.1016/j.foodhyd.2020.106454 · Cited by 258
Mayes, S. M., Davis, J., Scott, J., Aguilar, V., Zawko, S. A., Swinnea, S., Peterson, D. L., Hardy, J. G., & Schmidt, C. E. (2020) · Acta Biomaterialia · doi:10.1016/j.actbio.2020.02.027 · Cited by 64
Metadata
- Authors
- Pawde, S. M., & Deshmukh, K.
- Venue
- Journal of Applied Polymer Science
- Publisher
- Wiley
- Published
- 2008-05-27
- Volume
- 109
- Issue
- 5
- Pages
- 3431-3437
- ISSN
- 0021-8995 (ISSN-L)
- 1097-4628
- OpenAlex
- W2010883387
- Cited by
- 190
- References
- 2
- FWCI
- 1.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Characterization of polyvinyl alcohol/gelatin blend hydrogel films for biomedical applications. https://app.cochat.ai/papers/10.1002/app.28454
- The paper
- Pawde, S. M., & Deshmukh, K. (2008). Characterization of polyvinyl alcohol/gelatin blend hydrogel films for biomedical applications. Journal of Applied Polymer Science. https://doi.org/10.1002/app.28454
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.