Septation and valvar formation in the outflow tract of the embryonic chick heart
Open accessThe DOI matches its Crossref record.
Abstract
There is no agreement, in the chick, about the number of the endocardial cushions within the outflow tract or their pattern of fusion. Also, little is known of their relative contributions to the formation of the arterial valves, the subpulmonary infundibulum, and the arterial valvar sinuses. As the chick heart is an important model for studying septation of the outflow tract, our objective was to clarify these issues. Normal septation of the outflow tract was studied in a series of 60 staged chick hearts, by using stained whole‐mount preparations, serial sections, and scanning electron microscopy. A further six hearts were examined subsequent to hatching. At stage 21, two pairs of endocardial cushions were seen within the developing outflow tract. One pair was positioned proximally, with the other pair located distally. By stage 25, a third distal cushion had developed. This finding was before the appearance of two further, intercalated, endocardial cushions, also distally positioned, which were first seen at stage 29. In the arterial segment, the aortic and pulmonary channels were separated by the structure known as the aortopulmonary septum. The dorsal limb of this septum penetrated the distal dorsal cushion, whereas the ventral limb grew between the remaining two distal cushions, both of which were positioned ventrally. The three distal endocardial cushions, and the two intercalated endocardial cushions, contributed to the formation of the leaflets and sinuses of the arterial roots. The two proximal cushions gave rise to a transient septum, which later became transformed into the muscular component of the subpulmonary infundibulum. Concomitant with these changes, an extracardiac tissue plane was formed which separated this newly formed structure from the sinuses of the aortic root. Our study confirms that three endocardial cushions are positioned distally, and two proximally, within the developing outflow tract of the chick. The pattern of the distal cushions, and the position of the ventral limb of the aortopulmonary septum, differs significantly from that seen in mammals. Anat Rec 264:273–283, 2001. © 2001 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Heart Valve Development: Regulatory Networks in Development and Disease
Combs, M. D., & Yutzey, K. E. (2009) · Circulation Research · doi:10.1161/circresaha.109.201566 · Cited by 455
Developmental anatomy of the heart: a tale of mice and man
Wessels, A., & Sedmera, D. (2003) · Physiological Genomics · doi:10.1152/physiolgenomics.00033.2003 · Cited by 258
Fernández, B., Durán, A. C., Fernández-Gallego, T., Fernández, M. C., Such, M., Arqué, J. M., & Sans-Coma, V. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.07.044 · Cited by 230
Mechanical regulation of cardiac development
Lindsey, S. E. (2014) · Frontiers in Physiology · doi:10.3389/fphys.2014.00318 · Cited by 159
Quantifying blood flow and wall shear stresses in the outflow tract of chick embryonic hearts
Liu, A., Nickerson, A., Troyer, A., Yin, X., Cary, R., Thornburg, K., Wang, R., & Rugonyi, S. (2011) · Computers & Structures · doi:10.1016/j.compstruc.2011.03.003 · Cited by 44
Metadata
- Authors
- Qayyum, S. R., Webb, S., Anderson, R. H., Verbeek, F. J., Brown, N. A., & Richardson, M. K.
- Venue
- The Anatomical Record
- Publisher
- Wiley
- Published
- 2001-10-10
- Volume
- 264
- Issue
- 3
- Pages
- 273-283
- ISSN
- 0003-276X (ISSN-L)
- 1097-0185
- OpenAlex
- W2087930036
- Cited by
- 61
- References
- 0
- FWCI
- 0.87
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.