Statistical Analysis of the Angle of Intrusion of Porcine Ventricular Myocytes from Epicardium to Endocardium Using Diffusion Tensor Magnetic Resonance Imaging
Open accessThe DOI matches its Crossref record.
Abstract
Pairs of cylindrical knives were used to punch semicircular slices from the left basal, sub‐basal, equatorial, and apical ventricular wall of porcine hearts. The sections extended from the epicardium to the endocardium. Their semicircular shape compensated for the depth‐related changing orientation of the myocytes relative to the equatorial plane. The slices were analyzed by diffusion tensor magnetic resonance imaging. The primary eigenvector of the diffusion tensor was determined in each pixel to calculate the number and angle of intrusion of the long axis of the aggregated myocytes relative to the epicardial surface. Arrays of axially sectioned aggregates were found in which 53% of the approximately two million segments evaluated intruded up to ±15°, 40% exhibited an angle of intrusion between ±15° and ±45°, and 7% exceeded an angle of ±45°, the positive sign thereby denoting an epi‐ to endocardial spiral in clockwise direction seen from the apex, while a negative sign denotes an anticlockwise spiral from the epicardium to the endocardium. In the basal and apical slices, the greater number of segments intruded in positive direction, while in the sub‐basal and equatorial slices, negative angles of intrusion prevailed. The sampling of the primary eigenvectors was insensitive to postmortem decomposition of the tissue. In a previous histological study, we also documented the presence of large numbers of myocytes aggregated with their long axis intruding obliquely from the epicardial to the endocardial ventricular surfaces. We used magnetic resonance diffusion tensor imaging in this study to provide a comprehensive statistical analysis. Anat Rec, 290:1413–1423, 2007. © 2007 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Stephenson, R. S., Agger, P., Lunkenheimer, P. P., Zhao, J., Smerup, M., Niederer, P., Anderson, R. H., & Jarvis, J. C. (2016) · Clinical Anatomy · doi:10.1002/ca.22661 · Cited by 33
Self-citationHow are the cardiomyocytes aggregated together within the walls of the left ventricular cone?
Anderson, R. H., Niederer, P. F., Sanchez‐Quintana, D., Stephenson, R. S., & Agger, P. (2019) · Journal of Anatomy · doi:10.1111/joa.13027 · Cited by 22
“2006) and diffusion tensor magnetic resonance imaging (Schmid et al. 2007).”
BackgroundMethodSelf-citationAssessing Myocardial Architecture: The Challenges and Controversies
Agger, P., & Stephenson, R. S. (2020) · Journal of Cardiovascular Development and Disease · doi:10.3390/jcdd7040047 · Cited by 11
“Evidence now confirms that transmural angulations do indeed exist [4,13,55,79], and it is suggested they play a key role in cardiac function [54,56,80].”
Background
Metadata
- Authors
- Schmid, P., Lunkenheimer, P. P., Redmann, K., Rothaus, K., Jiang, X., Cryer, C. W., Jaermann, T., Niederer, P., Boesiger, P., & Anderson, R. H.
- Venue
- The Anatomical Record
- Publisher
- Wiley
- Published
- 2007-10-10
- Volume
- 290
- Issue
- 11
- Pages
- 1413-1423
- ISSN
- 1932-8486 (ISSN-L)
- 1932-8494
- OpenAlex
- W2087488116
- Cited by
- 35
- References
- 0
- FWCI
- 2.05
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.