The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Test–retest reliability of the peak knee adduction moment during walking in patients with medial compartment knee osteoarthritis
Abstract
Objective: To estimate the test–retest reliability of the peak external knee adduction moment during walking in patients with medial compartment knee osteoarthritis (OA), and to describe the interpretation of the reported values. Methods: A total of 31 patients diagnosed with knee OA confined primarily to the medial compartment underwent quantitative gait analyses during 2 separate test sessions at least 24 hours apart and within 1 week. The peak knee adduction moment was calculated for each patient at each session based on the mean of 5 walking trials. Reliability was estimated using the intraclass correlation coefficient (ICC 2,1) and the standard error of measurement (SEM). Results: The mean difference in peak adduction moments between test sessions was 0.1% body weight × height (BW × ht; 95% confidence interval [95% CI] −0.1, 0.3). The point estimate for the ICC was 0.86 (95% CI 0.73, 0.96). The point estimate for the SEM was 0.36% BW × ht (95% CI 0.29, 0.48). Conclusion: The ICC suggests that the peak knee adduction moment is appropriate for use when distinguishing among patients, for example, in studies of various interventions intended to decrease dynamic load on the knee medial compartment. The SEM illustrates the importance of considering measurement error and incorporating confidence levels when interpreting an individual patient's peak knee adduction moment value.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Measurement of lower extremity kinematics during level walking
Kadaba, M. P., Ramakrishnan, H. K., & Wootten, M. E. (1990) · Journal of Orthopaedic Research · doi:10.1002/jor.1100080310 · Cited by 3,216
Cited by
Etiopathogenesis of Osteoarthritis
Brandt, K. D., Dieppe, P., & Radin, E. (2009) · Medical Clinics of North America · doi:10.1016/j.mcna.2008.08.009 · Cited by 530
Etiopathogenesis of Osteoarthritis
Brandt, K. D., Dieppe, P., & Radin, E. L. (2008) · Rheumatic Disease Clinics of North America · doi:10.1016/j.rdc.2008.05.011 · Cited by 417
Bennell, K. L., Hunt, M. A., Wrigley, T. V., Hunter, D. J., McManus, F. J., Hodges, P. W., Li, L., & Hinman, R. S. (2010) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2010.01.010 · Cited by 291
Self-citationGait modification strategies for altering medial knee joint load: A systematic review
Simic, M., Hinman, R. S., Wrigley, T. V., Bennell, K. L., & Hunt, M. A. (2011) · Arthritis Care & Research · doi:10.1002/acr.20380 · Cited by 278
Self-citationForoughi, N., Smith, R., & Vanwanseele, B. (2009) · The Knee · doi:10.1016/j.knee.2008.12.007 · Cited by 270
Metadata
- Authors
- Birmingham, T. B., Hunt, M. A., Jones, I. C., Jenkyn, T. R., & Giffin, J. R.
- Venue
- Arthritis Care & Research
- Publisher
- Wiley
- Published
- 2007-07-30
- Volume
- 57
- Issue
- 6
- Pages
- 1012-1017
- ISSN
- 0893-7524 (ISSN-L)
- 1529-0123
- OpenAlex
- W2080612569
- Cited by
- 177
- References
- 3
- FWCI
- 5.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Test–retest reliability of the peak knee adduction moment during walking in patients with medial compartment knee osteoarthritis. https://app.cochat.ai/papers/10.1002/art.22899
- The paper
- Birmingham, T. B., Hunt, M. A., Jones, I. C., Jenkyn, T. R., & Giffin, J. R. (2007). Test–retest reliability of the peak knee adduction moment during walking in patients with medial compartment knee osteoarthritis. Arthritis Care & Research. https://doi.org/10.1002/art.22899
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.