CoChat

Removing per‐ and polyfluoroalkyl substances from groundwaters using activated carbon and ion exchange resin packed columns

Zeng, Chao, Atkinson, Ariel, Sharma, Naushita, Ashani, Harsh, Hjelmstad, Annika, Venkatesh, Krishishvar, Westerhoff, Paul · 2020 · AWWA Water Science
Cited by 105

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Abstract

Human exposure to per‐ and polyfluoroalkyl substances (PFAS) in drinking water is of growing concern as a result of increasing reports of occurrence and potential regulation. Adsorption of PFAS by granular activated carbon (GAC) or ion exchange (IX) resin is a suitable treatment technique. However, few studies compare PFAS removal in continuous flow GAC or IX adsorption systems using real drinking water sources. In this study, rapid small‐scale column tests (RSSCTs) were used to investigate the effects of PFAS type and chain length on adsorption by GAC and IX resin for six groundwaters used as drinking water supplies. Seven PFAS substances with chain lengths of C4–C9 were detected in the groundwaters with the sum of their concentrations (ΣPFAS) ranging from 156 to 7,044 ng/L. Adsorption capacities (qΣPFAS) were calculated to compare the removal capacity among different sorbents and qΣPFAS values ranged from 10.3 to 228 ng PFAS/mg sorbent after about 100,000 bed volumes treated. Coal‐based GACs had higher adsorption capacity compared with coconutshell‐based GAC, which was likely due to higher mesopore and macropore volumes. IX resins performed better than GAC in removing PFAS, but they were not effective in treating short‐chain perfluorocarboxylic acids (PFCAs). Perfluorosulfonic acids (PFSAs) broke through later than PFCAs with the same chain length. Within PFSA or PFCA classes, shorter‐chain PFAS species always broke through before longer‐chain PFAS. Statistical analysis demonstrated that PFAS with higher hydrophobicity and molecular weight are more amenable to GAC adsorption. Empirical models were developed and predicted PFAS breakthrough. By quantifying PFAS selectivity and removal efficiency, this work provides benchmark data for commercially available treatment technologies and guidance toward specific PFAS classes for which new treatment technologies may be most beneficial.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/aws2.1172

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Cited by

See all 105

Metadata

Authors
Zeng, C., Atkinson, A., Sharma, N., Ashani, H., Hjelmstad, A., Venkatesh, K., & Westerhoff, P.
Venue
AWWA Water Science
Publisher
Wiley
Published
2020-01
Volume
2
Issue
1
ISSN
2577-8161 (ISSN-L)
OpenAlex
W3008425439
Cited by
105
References
12
FWCI
4.26
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Removing per‐ and polyfluoroalkyl substances from groundwaters using activated carbon and ion exchange resin packed columns. https://app.cochat.ai/papers/10.1002/aws2.1172
The paper
Zeng, C., Atkinson, A., Sharma, N., Ashani, H., Hjelmstad, A., Venkatesh, K., & Westerhoff, P. (2020). Removing per‐ and polyfluoroalkyl substances from groundwaters using activated carbon and ion exchange resin packed columns. AWWA Water Science. https://doi.org/10.1002/aws2.1172

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.