Pharmacokinetic study of a novel sonosensitizer chlorin‐e6 and its sonodynamic anti‐cancer activity in hepatoma‐22 tumor‐bearing mice
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Purpose: The sonodynamically induced anti‐tumor effect of chlorin‐e6 (Ce6) was studied in mice bearing hepatoma‐22 solid tumors. Methods: In order to determine the optimum timing of ultrasound exposure after administration of Ce6, the Ce6 concentrations in plasma, skin, muscle and tumor were estimated by measuring the fluorescence intensity of tissue extractions with a fluorescence photometer based on the standard curve. A three‐dimensional optical imaging system (IVIS spectrum) was used further to characterize the distribution of Ce6 in H‐22 tumor. The anti‐tumor effects were estimated by measuring tumor size after sonodynamic therapy. Results: Similar pharmacokinetic trends of Ce6 in mice were observed either by fluorescence spectrophotometry or by bio‐optical imaging. The results also demonstrated that Ce6 has a preferential localization in tumors, but low accumulation and rapid clearance in normal tissues. The results of anti‐tumor effects revealed that at an ultrasound intensity of 4 W/cm 2 and a Ce6 dose of ≥10 mg/kg, a significant synergistic effect of ultrasound combined with Ce6 was observed, reducing the tumor volume significantly. Conclusion: Chlorin‐e6 is a potential sonosensitizer for fluorescence imaging as well as for sonodynamic therapy for cancer. The anti‐tumor effect of ultrasound could be enhanced in the presence of Ce6, which might be involved in a sonochemical mechanism. Copyright © 2011 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Determination of subcutaneous tumor size in athymic (nude) mice
Tomayko, M. M., & Reynolds, C. P. (1989) · Cancer Chemotherapy and Pharmacology · doi:10.1007/bf00300234 · Cited by 1,830
Cited by
Ultrasound‐Activated Sensitizers and Applications
Lin, X., Song, J., Chen, X., & Yang, H. (2020) · Angewandte Chemie International Edition · doi:10.1002/anie.201906823 · Cited by 501
A Review of Low-Intensity Ultrasound for Cancer Therapy
Wood, A. K. W., & Sehgal, C. M. (2015) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2014.11.019 · Cited by 345
Sonodynamic Therapy: Concept, Mechanism and Application to Cancer Treatment
McHale, A. P., Callan, J. F., Nomikou, N., Fowley, C., & Callan, B. (2016) · Advances in Experimental Medicine and Biology · doi:10.1007/978-3-319-22536-4_22 · Cited by 343
Treating cancer with sonodynamic therapy: A review
Costley, D., Mc Ewan, C., Fowley, C., McHale, A. P., Atchison, J., Nomikou, N., & Callan, J. F. (2015) · International Journal of Hyperthermia · doi:10.3109/02656736.2014.992484 · Cited by 327
Li, D., Yang, Y., Li, D., Pan, J., Chu, C., & Liu, G. (2021) · Small · doi:10.1002/smll.202101976 · Cited by 255
Metadata
- Authors
- Shi, H., Liu, Q., Qin, X., Wang, P., & Wang, X.
- Venue
- Biopharmaceutics & Drug Disposition
- Publisher
- Wiley
- Published
- 2011-08-03
- Volume
- 32
- Issue
- 6
- Pages
- 319-332
- ISSN
- 0142-2782 (ISSN-L)
- 1099-081X
- OpenAlex
- W1927362803
- Cited by
- 47
- References
- 1
- FWCI
- 2.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.