CoChat

Low power millimeter wave irradiation exerts no harmful effect on human keratinocytes in vitro

Open access
Szabo, Imre, Manning, Michael R., Radzievsky, Alexander A., Wetzel, Michele A., Rogers, Thomas J., Ziskin, Marvin C. · 2003 · Bioelectromagnetics
Cited by 25

The DOI matches its Crossref record.

Abstract

Low power millimeter wave (LP‐MW) irradiation has been successfully used in clinical practice as an independent and/or supplemental therapy in patients with various diseases. It is still not clear, however, whether exposed skin is directly affected by repeated LP‐MW irradiation and whether cells of the epidermis can be activated by the absorbed energy. Keratinocytes, the most numerous component of the epidermis are believed to manifest functional responses to physical stimuli. In this study we analyzed whether LP‐MW irradiation modulated the production of chemokines, including RANTES and IP‐10 of keratinocytes in vitro. We also investigated whether LP‐MW irradiation induces a heat stress reaction in keratinocytes, and stimulates heat shock protein 70 (Hsp70) production. Vital staining of keratinocytes with carboxyfluorescein succinimidyl ester and ethidium bromide was used to analyze the MW effect on the viability of adherent cells. In addition, we studied the effect of LP‐MW irradiation on intercellular gap junctional communication in keratinocyte monolayers by Lucifer yellow dye transfer. We found no significant changes in constitutive RANTES and inducible IP‐10 production following LP‐MW irradiation. LP‐MW exposure of keratinocyte monolayers did not alter Hsp70 production, unlike exposure to higher power MWs (HP‐MW) or hyperthermia (43 °C; 1 h). LP‐MW irradiation and hyperthermia did not alter the viability of adherent keratinocytes, while HP‐MW irradiation induced cellular damage within the beam area. Finally, we found no alteration in the gap junctional intercellular communication of keratinocytes following LP‐MW irradiation, which on the other hand, was significantly increased by hyperthermia. In summary, we detected no harmful effect of LP‐MW irradiation on both keratinocyte function and structure in vitro, although these cells were sensitive to higher MW power that developed heat stress reaction and cellular damage. Our results provide further evidence that LP‐MW irradiation does not induce evidence of skin inflammation or keratinocyte damage and that its clinical application appears to be safe. Bioelectromagnetics 24:165–173, 2003. © 2003 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/bem.10077

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Szabo, I., Manning, M. R., Radzievsky, A. A., Wetzel, M. A., Rogers, T. J., & Ziskin, M. C.
Venue
Bioelectromagnetics
Publisher
Wiley
Published
2003-03-12
Volume
24
Issue
3
Pages
165-173
ISSN
  • 0197-8462 (ISSN-L)
  • 1521-186X
OpenAlex
W2029056733
Cited by
25
References
0
FWCI
1.40
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.