Cardiovascular alterations in Macaca monkeys exposed to stationary magnetic fields: Experimental observations and theoretical analysis
The DOI matches its Crossref record.
Abstract
Simultaneous measurements were made of the electrocardiogram (ECG) and the intraarterial blood pressure of adult male Macaca monkeys during acute exposures to homogeneous stationary magnetic fields ranging in strength up to 1.5 tesla. An instantaneous, field strength‐dependent increase in the ECG signal amplitude at the locus of the T wave was observed in fields greater than 0.1 tesla. The temporal sequence of this signal in the ECG record and its reversibility following termination of the magnetic field exposure are consistent with an earlier suggestion that it arises from a magnetically induced aortic blood flow potential superimposed on the native T‐wave signal. No measurable alterations in blood pressure resulted from exposure to fields up to 1.5 tesla. This experimental finding is in agreement with theoretical calculations of the magnetohydrodynamic effect on blood flow in the major arteries of the cardiovascular system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Allen, P. J., Polizzi, G., Krakow, K., Fish, D. R., & Lemieux, L. (1998) · NeuroImage · doi:10.1006/nimg.1998.0361 · Cited by 912
GUIDELINES ON LIMITS OF EXPOSURE TO STATIC MAGNETIC FIELDS
(2009) · Health Physics · doi:10.1097/01.hp.0000343164.27920.4a · Cited by 455
Safety of Strong, Static Magnetic Fields
Schenck, J. F. (2000) · Journal of Magnetic Resonance Imaging · doi:10.1002/1522-2586(200007)12:1<2::aid-jmri2>3.0.co;2-v · Cited by 436
Electromagnetic effects—From cell biology to medicine
Funk, R. H. W., Monsees, T., & Özkucur, N. (2009) · Progress in Histochemistry and Cytochemistry · doi:10.1016/j.proghi.2008.07.001 · Cited by 423
Physical interactions of static magnetic fields with living tissues
Schenck, J. F. (2005) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2004.08.009 · Cited by 229
EEG-Informed fMRI: A Review of Data Analysis Methods
Abreu, R., Leal, A., & Figueiredo, P. (2018) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2018.00029 · Cited by 171
“…MRI scanner, namely: (1) bulk head rotation due to cardiac blood ejection (Bonmassar et al., 2002); (2) scalp expansion due to arterial pulsation (Debener et al., 2008); and (3) Hall effect caused by the pulsatile flow of the blood, which is an electrically conductive fluid (Tenforde et al., 1983).”
BackgroundCognitive, cardiac, and physiological safety studies in ultra high field magnetic resonance imaging
Kangarlu, A., Burgess, R. E., Zhu, H., Nakayama, T., Hamlin, R. L., Abduljalil, A. M., & Robitaille, P. M. L. (1999) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(99)00086-7 · Cited by 163
Magnetically induced electric fields and currents in the circulatory system
Tenforde, T. S. (2005) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2004.08.003 · Cited by 96
Self-citationNeuner, I., Arrubla, J., Felder, J., & Shah, N. J. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.06.048 · Cited by 48
“Three main mechanisms contribute to the generation of the artefact (Allen et al., 1998; Bonmassar et al., 2002; Debener et al., 2008; Huang-Hellinger et al., 1995; Mullinger et al., 2013; Müri et al., 1998; Tenforde et al., 1983; Yan et al., 2010):”
Influential
Metadata
- Authors
- Tenforde, T. S., Gaffey, C. T., Moyer, B. R., & Budlnger, T. F.
- Venue
- Bioelectromagnetics
- Publisher
- Wiley
- Published
- 1983-01
- Volume
- 4
- Issue
- 1
- Pages
- 1-9
- ISSN
- 0197-8462 (ISSN-L)
- 1521-186X
- OpenAlex
- W1985638499
- Cited by
- 133
- References
- 0
- FWCI
- 2.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.