The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Formulas for preparing phantom muscle tissue at various radiofrequencies
Abstract
The dielectric properties of various test samples of phantom tissue were measured using an automated and temperature‐controlled slotted line. The ingredients for phantom materials were determined for simulating high‐water content tissue at 13.56, 27.12, 40.68, 70, 100, 200, 300, 433, 750, 915, and 2,450 MHz. The ingredients consisted of water, TX‐150 (a gelling agent), sodium chloride, and polyethylene powder (200–2,450 MHz) or aluminum powder (13.56–100 MHz). The dielectric constant and conductivity of these materials at different temperatures (15, 22, 30°C) were characterized.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonionizing electromagnetic wave effects in biological materials and systems
Johnson, C. C., & Guy, A. W. (1972) · Proceedings of the IEEE · doi:10.1109/proc.1972.8728 · Cited by 851
Self-citationGuy, A. W. (1971) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.1968.1127484 · Cited by 454
Self-citationRF-field interactions with biological systems: Electrical properties and biophysical mechanisms
Schwan, H. P., & Foster, K. R. (1980) · Proceedings of the IEEE · doi:10.1109/proc.1980.11589 · Cited by 406
Schepps, J. L., & Foster, K. R. (1980) · Physics in Medicine & Biology · doi:10.1088/0031-9155/25/6/012 · Cited by 306
Therapeutic applications of electromagnetic power
Guy, A. W., Lehmann, J. F., & Stonebridge, J. B. (1974) · Proceedings of the IEEE · doi:10.1109/proc.1974.9385 · Cited by 305
Self-citationDielectric properties of animal tissues in vivo at frequencies 10 MHz – 1 GHz
Stuchly, M. A., Athey, T. W., Stuchly, S. S., Samaras, G. M., & Taylor, G. A. (1981) · Bioelectromagnetics · doi:10.1002/bem.2250020202 · Cited by 112
Cited by
Karacolak, T., Hood, A. Z., & Topsakal, E. (2008) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2008.919373 · Cited by 633
Tissue-mimicking phantom materials for narrowband and ultrawideband microwave applications
Lazebnik, M., Madsen, E. L., Frank, G. R., & Hagness, S. C. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/18/001 · Cited by 418
Kandadai, M. A., Raymond, J. L., & Shaw, G. J. (2012) · Materials Science and Engineering: C · doi:10.1016/j.msec.2012.07.024 · Cited by 102
Multi-disciplinary challenges in tissue modeling for wireless electromagnetic powering: a review
Bocan, K. N., Mickle, M. H., & Sejdic, E. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2748338 · Cited by 41
Metadata
- Authors
- Chou, C., Chen, G., Guy, A. W., & Luk, K. H.
- Venue
- Bioelectromagnetics
- Publisher
- Wiley
- Published
- 1984-01
- Volume
- 5
- Issue
- 4
- Pages
- 435-441
- ISSN
- 0197-8462 (ISSN-L)
- 1521-186X
- OpenAlex
- W2163954875
- Cited by
- 253
- References
- 6
- FWCI
- 7.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Formulas for preparing phantom muscle tissue at various radiofrequencies. https://app.cochat.ai/papers/10.1002/bem.2250050408
- The paper
- Chou, C., Chen, G., Guy, A. W., & Luk, K. H. (1984). Formulas for preparing phantom muscle tissue at various radiofrequencies. Bioelectromagnetics. https://doi.org/10.1002/bem.2250050408
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.