CoChat

Numerical dosimetry at power-line frequencies using anatomically based models

Gandhi, Om P., Chen, Jin-Yuan · 1992 · Bioelectromagnetics
Cited by 195

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

Abstract

We have used the finite-difference time-domain (FDTD) method to calculate induced current densities in a 1.31-cm (nominal 1/2 in) resolution anatomically based model of the human body for exposure to purely electric, purely magnetic, and combined electric and magnetic fields at 60 Hz. This model based on anatomic sectional diagrams consists of 45,024 cubic cells of dimension 1.31 cm for which the volume-averaged tissue properties are prescribed. It is recognized that the conductivities of several tissues (skeletal muscle, bone, etc.) are highly anisotropic for power-line frequencies. This has, however, been neglected in the first instance and will be included in future calculations. Because of the quasi-static nature of coupling at the power-line frequencies, a higher quasi-static frequency f' may be used for irradiation of the model, and the internal fields E' thus calculated can be scaled back to the frequency of interest, e.g., 60 Hz. Since in the FDTD method one needs to calculate in the time domain until convergence is obtained (typically 3-4 time periods), this frequency scaling to 5-10 MHz for f' reduces the needed number of iterations by over 5 orders of magnitude. The data calculated for the induced current and its variation as a function of height are in excellent agreement with the data published in the literature. The average current densities calculated for the various sections of the body for the magnetic field component (H) are considerably smaller (by a factor of 20-50) than those due to the vertically polarized electric field component when the ratio E/H is 377 ohms. We have also used the previously described impedance method to calculate the induced current densities for the anatomically based model of the human body for the various orientations of the time-varying magnetic fields, namely from side to side, front to back, or from top to bottom of the model, respectively.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/bem.2250130706

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Metadata

Authors
Gandhi, O. P., & Chen, J.-Y.
Venue
Bioelectromagnetics
Publisher
Wiley
Published
1992
Volume
13
Issue
S1
Pages
43-60
ISSN
  • 0197-8462 (ISSN-L)
  • 1521-186X
OpenAlex
W2041773054
Cited by
195
References
20
FWCI
4.63
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.