The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Development of the female voxel phantom, NAOMI, and its application to calculations of induced current densities and electric fields from applied low frequency magnetic and electric fields
Abstract
This paper outlines the development of a 2 mm resolution voxel model, NAOMI (aNAtOMIcal model), designed to be representative of the average adult female. The primary medical imaging data were derived from a high-resolution MRI scan of a 1.65 m tall, 23 year old female subject with a mass of 58 kg. The model was rescaled to a height of 1.63 m and a mass of 60 kg, the dimensions of the International Commission on Radiological Protection reference adult female. There are 41 tissue types in the model. The application of NAOMI to the calculations of induced current densities and electric fields from applied low frequency magnetic and electric fields is described. Comparisons are made with values from the male voxel model, NORMAN. The calculations were extended from 50 Hz up to 10 MHz. External field reference levels are compared with the ICNIRP guidelines.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/002 · Cited by 4,270
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/003 · Cited by 4,175
The dielectric properties of biological tissues: I. Literature survey
Gabriel, C., Gabriel, S., & Corthout, E. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/001 · Cited by 3,156
Computational Electromagnetics: The Finite-Difference Time-Domain Method
Taflove, A., Hagness, S. C., & Piket-May, M. (2005) · The Electrical Engineering Handbook · doi:10.1016/b978-012170960-0/50046-3 · Cited by 1,514
Computerized three‐dimensional segmented human anatomy
Zubal, I. G., Harrell, C. R., Smith, E. O., Rattner, Z., Gindi, G., & Hoffer, P. B. (1994) · Medical Physics · doi:10.1118/1.597290 · Cited by 1,103
Nagaoka, T., Watanabe, S., Sakurai, K., Kunieda, E., Watanabe, S., Taki, M., & Yamanaka, Y. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/1/001 · Cited by 774
Basic anatomical and physiological data for use in radiological protection : reference values
Valentin, J. (2002) · Medical Entomology and Zoology · Cited by 680
Herbertz, J. (1998) · PubMed · Cited by 597
Dimbylow, P. J. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/3/003 · Cited by 284
Self-citation
Cited by
Gosselin, M.-C., Neufeld, E., Moser, H., Huber, E., Farcito, S., Gerber, L., Jedensjö, M., Hilber, I., Gennaro, F. D., Lloyd, B., et al. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/18/5287 · Cited by 520
Kainz, W., Neufeld, E., Bolch, W. E., Graff, C. G., Kim, C. H., Kuster, N., Lloyd, B., Morrison, T., Segars, P., Yeom, Y. S., et al. (2019) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2018.2883437 · Cited by 109
Laissaoui, A., Nekhoul, B., Mezoued, S., & Poljak, D. (2017) · Automatika · doi:10.1080/00051144.2018.1435341 · Cited by 2
Metadata
- Authors
- Dimbylow, P.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2005-02-24
- Volume
- 50
- Issue
- 6
- Pages
- 1047-1070
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W1994943748
- Cited by
- 276
- References
- 19
- FWCI
- 8.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Development of the female voxel phantom, NAOMI, and its application to calculations of induced current densities and electric fields from applied low frequency magnetic and electric fields. https://app.cochat.ai/papers/10.1088/0031-9155/50/6/002
- The paper
- Dimbylow, P. (2005). Development of the female voxel phantom, NAOMI, and its application to calculations of induced current densities and electric fields from applied low frequency magnetic and electric fields. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/50/6/002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.