CoChat

Light from maillard reaction: Photon counting, emission spectrum, photography and visual perception

Wondrak, Georg, Pier, Thomas, Tressl, Roland · 1995 · Journal of Bioluminescence and Chemiluminescence

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Abstract

Several authors have reported on high‐sensitivity measurement of oxygen‐dependent low‐level chemiluminescence (CL) from Maillard reactions (MR), i.e. nonenzymatic amino‐carbonyl reactions between reducing sugars and amino acids (also referred to as nonenzymatic browning). Here we report for the first time, that light from Maillard reactions can be seen by the human eye and also can be photographed. In parallel with visual perception and photography CL was monitored by means of a CL‐detection programme of a liquid scintillation counter (LSC, single photon rate counting). CL emission spectrum was recorded by a monochromator‐microchannel plate photomultiplier arrangement. CL intensity from reaction of 6‐aminocaproic acid with D‐ribose (200 mg each) in 5 mL H 2 O at pH 11 at 95°C was high enough for visual perception after adaptation to absolute darkness. Reaction in dimethylsulphoxide (DMSO) exhibited strongly enhanced CL (10 mg each in 5 mL were sufficient for visual detection) and could be photographed (15 minutes' exposure, ASA 6400); all characteristics of Maillard specific CL (O 2‐dependence, no CL from nonreducing sugars, inhibition by sulphur compounds) remained. Visual detection of CL and measurement by LSC were in full concordance. The CL emission spectrum showed two broad peaks at around 500 nm and 695 nm. Fluorescence emission of the brown reaction mixture matched the bluegreen part of the CL emission spectrum. Emission of visible light during Maillard reactions may partly originate from oxygen‐dependent generation of excited states and energy transfer to simultaneously formed fluorescent products of the browning reaction.

Overview

Integrity signals

Registry

Crossref · 10.1002/bio.1170100504

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 13 references

Research works printed but not linked: 1

  1. Karatani H, 1994, Polyol chemiluminescence induced by mediated oxidation, J Biolumin Chemilumin, 9, 292

Cited by

See all 17

Metadata

Authors
Wondrak, G., Pier, T., & Tressl, R.
Affiliations
Technische Universität Berlin (DE)
Venue
Journal of Bioluminescence and Chemiluminescence
Publisher
Wiley
Published
1995-09
Volume
10
Issue
5
Pages
277-284
ISSN
  • 0884-3996 (ISSN-L)
  • 1099-1271
OpenAlex
W1981220319
Cited by
17
References
13
Citations by year
2026: 1 · 2023: 1 · 2022: 1 · 2020: 1 · 2018: 1 · 2014: 1
FWCI
1.11
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Bioluminescence and Chemiluminescence (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Clinical Biochemistry › Advanced Glycation End Products research
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › bioluminescence and chemiluminescence research
  • Life Sciences › Agricultural and Biological Sciences › Food Science › Potato Plant Research
Keywords
Maillard reaction, chemiluminescence, non-enzymatic browning, light perception, emission spectra, 6-aminocaproic acid, D-ribose, dimethyl sulfoxide, excited states
MeSH terms
Amino Acids, Carbohydrates, Dimethyl Sulfoxide, Humans, Kinetics, Light, Luminescent Measurements, Photography, Sensitivity and Specificity, Structure-Activity Relationship, Visual Perception, Water, Maillard Reaction, Photons

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.