The DOI matches its Crossref record.
Improved rapid sampling for in vivo kinetics of intracellular metabolites in Saccharomyces cerevisiae
Abstract
An integrated approach is used to develop a rapid sampling strategy for the quantitative analysis of in vivo kinetic behavior based on measured concentrations of intracellular metabolites in Saccharomyces cerevisiae. Emphasis is laid on small sample sizes during sampling and analysis. Subsecond residence times are accomplished by minimizing the dead volume of the sterile sampling system and by maximizing flow rates through application of vacuum to the sampling tubes in addition to the overpressure in the fermenter. A specially designed sample tube adapter facilitates sampling intervals of 4 to 5 s for various test tube types. Statistical analysis of the results obtained from enzymatic and liquid chromatography mass spectrometry (LC‐MSMS) analysis of the metabolite concentrations was used to optimize the sampling protocol. The most notable improvement is reached through the introduction of vacuum drying of the cell extract. The presented system is capable of reliably dealing with fermenter samples as small as 1‐g with a variation of less than 3%, and is thus ideally suited for intracellular measurements on small, lab‐scale fermenters. © 2001 John Wiley & Sons, Inc. Biotechnol Bioeng 75: 406–415, 2001.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bajad, S. U., Lu, W., Kimball, E. H., Yuan, J., Peterson, C., & Rabinowitz, J. D. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.05.019 · Cited by 592
Metabolite Measurement: Pitfalls to Avoid and Practices to Follow
Lu, W., Su, X., Klein, M. S., Lewis, I. A., Fiehn, O., & Rabinowitz, J. D. (2017) · Annual Review of Biochemistry · doi:10.1146/annurev-biochem-061516-044952 · Cited by 462
Wu, L., Mashego, M. R., van Dam, J. C., Proell, A. M., Vinke, J. L., Ras, C., van Winden, W. A., van Gulik, W. M., & Heijnen, J. J. (2005) · Analytical Biochemistry · doi:10.1016/j.ab.2004.09.001 · Cited by 421
Self-citationGlobal metabolite analysis of yeast: evaluation of sample preparation methods
Villas‐Bôas, S. G., Højer‐Pedersen, J., Åkesson, M., Smedsgaard, J., & Nielsen, J. (2005) · Yeast · doi:10.1002/yea.1308 · Cited by 400
Quantitative Evaluation of Intracellular Metabolite Extraction Techniques for Yeast Metabolomics
Canelas, A. B., ten Pierick, A., Ras, C., Seifar, R. M., van Dam, J. C., van Gulik, W. M., & Heijnen, J. J. (2009) · Analytical Chemistry · doi:10.1021/ac900999t · Cited by 360
Self-citation
Metadata
- Authors
- Lange, H. C., Eman, M., van Zuijlen, G., Visser, D., van Dam, J. C., Frank, J., de Mattos, M. J. T., & Heijnen, J. J.
- Venue
- Biotechnology and Bioengineering
- Publisher
- Wiley
- Published
- 2001-10-15
- Volume
- 75
- Issue
- 4
- Pages
- 406-415
- ISSN
- 0006-3592 (ISSN-L)
- 1097-0290
- OpenAlex
- W2073253360
- Cited by
- 194
- References
- 0
- FWCI
- 2.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Improved rapid sampling for in vivo kinetics of intracellular metabolites in Saccharomyces cerevisiae. https://app.cochat.ai/papers/10.1002/bit.10048
- The paper
- Lange, H. C., Eman, M., van Zuijlen, G., Visser, D., van Dam, J. C., Frank, J., de Mattos, M. J. T., & Heijnen, J. J. (2001). Improved rapid sampling for in vivo kinetics of intracellular metabolites in Saccharomyces cerevisiae. Biotechnology and Bioengineering. https://doi.org/10.1002/bit.10048
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.