CoChat

Inline characterization of cell concentration and cell volume in agitated bioreactors using in situ microscopy: Application to volume variation induced by osmotic stress

Camisard, V., Brienne, J.‐P., Baussart, H., Hammann, J., Suhr, H. · 2002 · Biotechnology and Bioengineering
Cited by 62

The DOI matches its Crossref record.

Abstract

A new in situ microscope (ISM) was developed and tested to perform in‐line monitoring of average cell volume and cell concentration in agitated cultures subjected to osmotic stress. The ISM is directly immersed into the agitated broth in a bioreactor and generates still images of cells by using pulsed luminescent diode illumination and a virtual probe volume defined by depth of focus. This technique allows the acquisition of microscopic still images without mechanical sampling techniques. The front end of the sensor fits into a standard 25‐mm port and it can be steam sterilized together with the bioreactor. The automatic image evaluation generates signals of the cell concentration and the average cell volume with a time resolution of a few minutes per data point (if a 200 MHz PC is used). Without the need for evaluation, the images can be acquired and stored at a rate of one image per 0.6 s. Hansenula anomala was cultivated as batch fermentation and monitored inline with the ISM. The ISM signal of the cell concentration agreed well with referential growth curves that were obtained from counting with a hemocytometer. The ISM signal of the average cell volume shows a gradual volume reduction as a result of the aging of the culture, and it monitors an abrupt and strong cell contraction if osmotic shocks are generated in the bioreactor. Systematic in vitro studies of osmotic shocks were performed by applying the ISM to agitated culture samples of H. anomala. The volume signal of H. anomala during osmotic shocks showed a very fast cell contraction within less than a second. Within half an hour after the shocks, no signal drifts were observed, which would indicate volume restoration. These findings suggest that the ISM volume signal can be used as an inline indicator of osmotic stress in cell cultures. © 2002 Wiley Periodicals, Inc. Biotechnol Bioeng 78: 73–80, 2002; DOI 10.1002/bit.10178

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/bit.10178

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Camisard, V., Brienne, J. ‐., Baussart, H., Hammann, J., & Suhr, H.
Venue
Biotechnology and Bioengineering
Publisher
Wiley
Published
2002-02-04
Volume
78
Issue
1
Pages
73-80
ISSN
  • 0006-3592 (ISSN-L)
  • 1097-0290
OpenAlex
W2017060042
Cited by
62
References
0
FWCI
2.30
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.