Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 216

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Characterization of gas–liquid mass transfer phenomena in microtiter plates

Hermann, Robert, Lehmann, Mathias, Büchs, Jochen·2003·Biotechnology and Bioengineering

Abstract

Gas–liquid mass transfer properties of shaken 96‐well microtiter plates were characterized using a recently described method. The maximum oxygen transfer capacity (OTR max), the specific mass transfer area (a), and the mass transfer coefficient (k L) in a single well were determined at different shaking intensities (different shaking frequencies and shaking diameters at constant filling volume) and different filling volumes by means of sulfite oxidation as a chemical model system. The shape (round and square cross‐sections) and the size (up to 2 mL maximum filling volume) of a microtiter plate well were also considered as influencing parameters. To get an indication of the hydrodynamic behavior of the liquid phase in a well, images were taken during shaking and the liquid height derived as a characteristic parameter. The investigations revealed that the OTR max is predominantly dependent on the specific mass transfer area (a) for the considered conditions in round‐shaped wells. The mass transfer coefficient (k L) in round‐shaped wells remains at a nearly constant value of about 0.2 m/h for all shaking intensities, thus within the range reported in the literature for surface‐aerated bioreactors. The OTR max in round‐shaped wells is strongly influenced by the interfacial tension, determined by the surface tension of the medium used and the surface properties of the well material. Up to a specific shaking intensity the liquid surface in the wells remains horizontal and no liquid movement can be observed. This critical shaking intensity must be exceeded to overcome the surface tension and, thus, to increase the liquid height and enlarge the specific mass transfer area. This behavior is solely specific to microtiter plates and has not yet been observed for larger shaking bioreactors such as shaking flasks. In square‐shaped microtiter plate wells the corners act as baffles and cause a significant increase of OTR max, a, and k L. An OTR max of up to 0.15 mol/L/h can be reached in square‐shaped wells. © 2002 Wiley Periodicals, Inc. Biotechnol Bioeng 81: 178–186, 2003.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/bit.10456

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 216

Metadata

Authors
Hermann, R., Lehmann, M., & Büchs, J.
Venue
Biotechnology and Bioengineering
Publisher
Wiley
Published
2002-11-25
Volume
81
Issue
2
Pages
178-186
ISSN
  • 0006-3592 (ISSN-L)
  • 1097-0290
OpenAlex
W2107031198
Cited by
216
References
1
FWCI
8.05
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Characterization of gas–liquid mass transfer phenomena in microtiter plates. https://app.cochat.ai/papers/10.1002/bit.10456
The paper
Hermann, R., Lehmann, M., & Büchs, J. (2003). Characterization of gas–liquid mass transfer phenomena in microtiter plates. Biotechnology and Bioengineering. https://doi.org/10.1002/bit.10456

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.