Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 258

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

MIRACLE: mass isotopomer ratio analysis of U‐13C‐labeled extracts. A new method for accurate quantification of changes in concentrations of intracellular metabolites

Mashego, M. R., Wu, L., Van Dam, J. C., Ras, C., Vinke, J. L., Van Winden, W. A., Van Gulik, W. M., Heijnen, J. J.·2004·Biotechnology and Bioengineering

Abstract

First, we report the application of stable isotope dilution theory in metabolome characterization of aerobic glucose limited chemostat culture of S. cerevisiae CEN.PK 113‐7D using liquid chromatography‐electrospray ionization MS/MS (LC‐ESI‐MS/MS). A glucose‐limited chemostat culture of S. cerevisiae was grown to steady state at a specific growth rate (μ) = 0.05 h−1 in a medium containing only naturally labeled (99% U‐12 C, 1% U‐13 C) carbon source. Upon reaching steady state, defined as 5 volume changes, the culture medium was switched to chemically identical medium except that the carbon source was replaced with 100% uniformly (U) 13 C labeled stable carbon isotope, fed for 4 h, with sampling every hour. We observed that within a period of 1 h ∼80% of the measured glycolytic metabolites were U‐13 C‐labeled. Surprisingly, during the next 3 h no significant increase of the U‐13 C‐labeled metabolites occurred. Second, we demonstrate for the first time the LC‐ESI‐MS/MS‐based quantification of intracellular metabolite concentrations using U‐13 C‐labeled metabolite extracts from chemostat cultivated S. cerevisiae cells, harvested after 4 h of feeding with 100% U‐13 C‐labeled medium, as internal standard. This method is hereby termed “Mass Isotopomer Ratio Analysis of U‐13 C Labeled Extracts” (MIRACLE). With this method each metabolite concentration is quantified relative to the concentration of its U‐13 C‐labeled equivalent, thereby eliminating drawbacks of LC‐ESI‐MS/MS analysis such as nonlinear response and matrix effects and thus leads to a significant reduction of experimental error and work load (i.e., no spiking and standard additions). By coextracting a known amount of U‐13 C labeled cells with the unlabeled samples, metabolite losses occurring during the sample extraction procedure are corrected for. © 2004 Wiley Periodicals, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/bit.10907

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • Quantitative analysis of complex protein mixtures using isotope-coded affinity tags

    Gygi, S. P., Rist, B., Gerber, S. A., Turecek, F., Gelb, M. H., & Aebersold, R. (1999) · Nature Biotechnology · doi:10.1038/13690 · Cited by 4,683 · cited 1×

    “The theory is routinely applied in an isotope-code affinity tag (ICAT) approach for proteomics studies to quantify relative abundance of proteins in biological samples (Govorun and Archakov, 2002; Griffin and Aebersold, 2001; Gygi et al., 1999; Ideker et al., 2001; Nyman, 2001).”
    Method

Show all 1 references

Cited by

See all 258

Metadata

Authors
Mashego, M. R., Wu, L., Van Dam, J. C., Ras, C., Vinke, J. L., Van Winden, W. A., Van Gulik, W. M., & Heijnen, J. J.
Venue
Biotechnology and Bioengineering
Publisher
Wiley
Published
2004-01-20
Volume
85
Issue
6
Pages
620-628
ISSN
  • 0006-3592 (ISSN-L)
  • 1097-0290
OpenAlex
W2155151971
Cited by
258
References
1
FWCI
7.11
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: MIRACLE: mass isotopomer ratio analysis of U‐13C‐labeled extracts. A new method for accurate quantification of changes in concentrations of intracellular metabolites. https://app.cochat.ai/papers/10.1002/bit.10907
The paper
Mashego, M. R., Wu, L., Van Dam, J. C., Ras, C., Vinke, J. L., Van Winden, W. A., Van Gulik, W. M., & Heijnen, J. J. (2004). MIRACLE: mass isotopomer ratio analysis of U‐13C‐labeled extracts. A new method for accurate quantification of changes in concentrations of intracellular metabolites. Biotechnology and Bioengineering. https://doi.org/10.1002/bit.10907

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.