The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Quasi‐continuous combined scattered light and fluorescence measurements: A novel measurement technique for shaken microtiter plates
Abstract
A novel quasi‐continuous on‐line measuring technique for shaken microtiter plates is presented. Light scattering as well as intracellular and/or protein fluorescence (e.g. NADH, YFP) is measured during the shaking procedure, thus allowing a process monitoring of 96 different simultaneous cultures in a microtiter plate. In contrast to existing measurement techniques, the shaking process does not have to be stopped to take the measurements, thus avoiding the corresponding interruption of the cultures' oxygen supply and any unpredictable effects on the cultures. Experiments were conducted with E. coli in LB, TB, and MOPS minimal medium and V. natriegens in modified LB and TB media. Intensity curves of scattered light and NADH fluorescence were used to distinguish different lag phases, growth velocities, or inoculation densities. Data from this new method corresponded well to the off‐line measured optical densities and to the oxygen transfer rates of cultures run in simultaneously conducted shake flask experiments at equivalent oxygen transfer capacities. With the aid of yellow fluorescence protein fused to interleukin‐6 the optimal induction time of an expressing E. coli strain could be determined by on‐line monitoring of product formation. Thus, this measuring technique enables the researcher to evaluate and to discriminate different cultures on a screening level and to improve screening conditions, process development and scale‐up. © 2005 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Introduction to advantages and problems of shaken cultures
Büchs, J. (2001) · Biochemical Engineering Journal · doi:10.1016/s1369-703x(00)00106-6 · Cited by 388
Self-citationTwo-Dimensional Fluorescence Spectroscopy: A New Tool for On-Line Bioprocess Monitoring
Marose, S., Lindemann, C., & Scheper, T. (1998) · Biotechnology Progress · doi:10.1021/bp970124o · Cited by 190
Cited by
High-throughput screening for ionic liquids dissolving (ligno-)cellulose
Zavrel, M., Bross, D., Funke, M., Büchs, J., & Spiess, A. C. (2009) · Bioresource Technology · doi:10.1016/j.biortech.2008.11.052 · Cited by 700
Self-citationLara, A. R., Galindo, E., Ramírez, O. T., & Palomares, L. A. (2006) · Molecular Biotechnology · doi:10.1385/mb:34:3:355 · Cited by 406
Rowlett, V. W., Mallampalli, V. K. P. S., Karlstaedt, A., Dowhan, W., Taegtmeyer, H., Margolin, W., & Vitrac, H. (2017) · Journal of Bacteriology · doi:10.1128/jb.00849-16 · Cited by 283
Bioprocessing of plant cell cultures for mass production of targeted compounds
Georgiev, M. I., Weber, J., & Maciuk, A. (2009) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-009-2049-x · Cited by 276
Kensy, F., Zang, E., Faulhammer, C., Tan, R.-K., & Büchs, J. (2009) · Microbial Cell Factories · doi:10.1186/1475-2859-8-31 · Cited by 253
Self-citation
Metadata
- Authors
- Samorski, M., Müller‐Newen, G., & Büchs, J.
- Venue
- Biotechnology and Bioengineering
- Publisher
- Wiley
- Published
- 2005-06-29
- Volume
- 92
- Issue
- 1
- Pages
- 61-68
- ISSN
- 0006-3592 (ISSN-L)
- 1097-0290
- OpenAlex
- W2149079511
- Cited by
- 179
- References
- 2
- FWCI
- 3.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quasi‐continuous combined scattered light and fluorescence measurements: A novel measurement technique for shaken microtiter plates. https://app.cochat.ai/papers/10.1002/bit.20573
- The paper
- Samorski, M., Müller‐Newen, G., & Büchs, J. (2005). Quasi‐continuous combined scattered light and fluorescence measurements: A novel measurement technique for shaken microtiter plates. Biotechnology and Bioengineering. https://doi.org/10.1002/bit.20573
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.