CoChat

Engineered blood and lymphatic capillaries in 3‐D VEGF‐fibrin‐collagen matrices with interstitial flow

Open access
Helm, Cara‐Lynn E., Zisch, Andreas, Swartz, Melody A. · 2007 · Biotechnology and Bioengineering
Cited by 143

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

In vitro endothelial cell organization into capillaries is a long standing challenge of tissue engineering. We recently showed the utility of low level interstitial flow in guiding the organization of endothelial cells through a 3‐D fibrin matrix‐containing covalently bound vascular endothelial growth factor (VEGF). Here this synergistic phenomenon was extended to explore the effects of matrix composition on in vitro capillary morphogenesis of human blood versus lymphatic endothelial cells (BECs and LECs). Different mixtures of fibrin and collagen were used in conjunction with constant concentrations of matrix‐bound VEGF and slow interstitial flow over 10 days. Interestingly, the BECs and LECs each showed a distinct preference in terms of organization for matrix composition: LECs organized the most extensively in a fibrin‐only matrix, while BEC organization was optimized in the compliant collagen‐containing matrices. Furthermore, the BECs and LECs produced architecturally different structures; while BECs organized in thick, branched networks containing wide lumen, the LECs were elongated into slender, overlapping networks with fine lumen. These data demonstrate the importance of the 3‐D matrix composition in facilitating and coordinating BEC and LEC capillary morphogenesis, which is important for in vitro vascularization of engineered tissues. Biotechnol. Bioeng. 2007;96: 167–176. © 2006 Wiley Periodicals, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/bit.21185

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • The biology of VEGF and its receptors

    Ferrara, N., Gerber, H.-P., & LeCouter, J. (2003) · Nature Medicine · doi:10.1038/nm0603-669 · Cited by 9,591 · cited 7×

    “In addition, when applied as an implanted fibrin matrix in vivo, this matrix-binding variant of VEGF121 produced patent capillary vessels as opposed to the leaky variety elicited by soluble VEGF121 in the same system (Ehrbar et al., 2004).”
    BackgroundInfluential
  • Cutaneous Wound Healing

    Singer, A. J., & Clark, R. A. F. (1999) · New England Journal of Medicine · doi:10.1056/nejm199909023411006 · Cited by 6,106

Show all 2 references

Cited by

Metadata

Authors
Helm, C. E., Zisch, A., & Swartz, M. A.
Venue
Biotechnology and Bioengineering
Publisher
Wiley
Published
2006-08-31
Volume
96
Issue
1
Pages
167-176
ISSN
  • 0006-3592 (ISSN-L)
  • 1097-0290
OpenAlex
W2150305156
Cited by
143
References
2
FWCI
5.61
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.