The DOI matches its Crossref record.
Response of a concentrated monoclonal antibody formulation to high shear
Open accessAbstract
There is concern that shear could cause protein unfolding or aggregation during commercial biopharmaceutical production. In this work we exposed two concentrated immunoglobulin‐G1 (IgG1) monoclonal antibody (mAb, at >100 mg/mL) formulations to shear rates between 20,000 and 250,000 s−1 for between 5 min and 30 ms using a parallel‐plate and capillary rheometer, respectively. The maximum shear and force exposures were far in excess of those expected during normal processing operations (20,000 s−1 and 0.06 pN, respectively). We used multiple characterization techniques to determine if there was any detectable aggregation. We found that shear alone did not cause aggregation, but that prolonged exposure to shear in the stainless steel parallel‐plate rheometer caused a very minor reversible aggregation (<0.3%). Additionally, shear did not alter aggregate populations in formulations containing 17% preformed heat‐induced aggregates of a mAb. We calculate that the forces applied to a protein by production shear exposures (<0.06 pN) are small when compared with the 140 pN force expected at the air–water interface or the 20–150 pN forces required to mechanically unfold proteins described in the atomic force microscope (AFM) literature. Therefore, we suggest that in many cases, air‐bubble entrainment, adsorption to solid surfaces (with possible shear synergy), contamination by particulates, or pump cavitation stresses could be much more important causes of aggregation than shear exposure during production. Biotechnol. Bioeng. 2009;103: 936–943. © 2009 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Filipe, V., Hawe, A., & Jiskoot, W. (2010) · Pharmaceutical Research · doi:10.1007/s11095-010-0073-2 · Cited by 1,885
Protein aggregation—Pathways and influencing factors
Wang, W., Nema, S., & Teagarden, D. (2010) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2010.02.025 · Cited by 806
Recent advances in large-scale production of monoclonal antibodies and related proteins
Shukla, A. A., & Thömmes, J. (2010) · Trends in Biotechnology · doi:10.1016/j.tibtech.2010.02.001 · Cited by 578
Aggregates in monoclonal antibody manufacturing processes
Vázquez‐Rey, M., & Lang, D. A. (2011) · Biotechnology and Bioengineering · doi:10.1002/bit.23155 · Cited by 479
Physicochemical Stability of Monoclonal Antibodies: A Review
Le Basle, Y., Chennell, P., Tokhadze, N., Astier, A., & Sautou, V. (2020) · Journal of Pharmaceutical Sciences · doi:10.1016/j.xphs.2019.08.009 · Cited by 429
Metadata
- Authors
- Bee, J. S., Stevenson, J. L., Mehta, B., Svitel, J., Pollastrini, J., Platz, R., Freund, E., Carpenter, J. F., & Randolph, T. W.
- Venue
- Biotechnology and Bioengineering
- Publisher
- Wiley
- Published
- 2009-04-15
- Volume
- 103
- Issue
- 5
- Pages
- 936-943
- ISSN
- 0006-3592 (ISSN-L)
- 1097-0290
- OpenAlex
- W1987405744
- Cited by
- 203
- References
- 0
- FWCI
- 4.20
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Response of a concentrated monoclonal antibody formulation to high shear. https://app.cochat.ai/papers/10.1002/bit.22336
- The paper
- Bee, J. S., Stevenson, J. L., Mehta, B., Svitel, J., Pollastrini, J., Platz, R., Freund, E., Carpenter, J. F., & Randolph, T. W. (2009). Response of a concentrated monoclonal antibody formulation to high shear. Biotechnology and Bioengineering. https://doi.org/10.1002/bit.22336
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.