Rapid whole monoclonal antibody analysis by mass spectrometry: An Ultra scale‐down study of the effect of harvesting by centrifugation on the post‐translational modification profile
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
With the trend towards the generation and production of increasing numbers of complex biopharmaceutical (protein based) products, there is an increased need and requirement to characterize both the product and production process in terms of robustness and reproducibility. This is of particular importance for products from mammalian cell culture which have large molecular structures and more often than not complex post‐translational modifications (PTMs) that can impact the efficacy, stability and ultimately the safety of the final product. It is therefore vital to understand how the operating conditions of a bioprocess affect the distribution and make up of these PTMs to ensure a consistent quality and activity in the final product. Here we have characterized a typical bioprocess and determined (a) how the time of harvest from a mammalian cell culture and, (b) through the use of an ultra scale‐down mimic how the nature of the primary recovery stages, affect the distribution and make up of the PTMs observed on a recombinant IgG 4 monoclonal antibody. In particular we describe the use of rapid whole antibody analysis by mass spectrometry to analyze simultaneously the changes that occur to the cleavage of heavy chain C‐terminal lysine residues and the glycosylation pattern, as well as the presence of HL dimers. The time of harvest was found to have a large impact upon the range of glycosylation patterns observed, but not upon C‐terminal lysine cleavage. The culture age had a profound impact on the ratio of different glycan moieties found on antibody molecules. The proportion of short glycans increased (e.g., (G0F)2 20–35%), with an associated decrease in the proportion of long glycans with culture age (e.g., (G2F)2 7–4%, and G1F/G2F from 15.2% to 7.8%). Ultra scale‐down mimics showed that subsequent processing of these cultures did not change the post‐translational modifications investigated, but did increase the proportion of half antibodies present in the process stream. The combination of ultra scale‐down methodology and whole antibody analysis by mass spectrometry has demonstrated that the effects of processing on the detailed molecular structure of a monoclonal antibody can be rapidly determined early in the development process. In this study we have demonstrated this analysis to be applicable to critical process design decisions (e.g., time of harvest) in terms of achieving a desired molecular structure, but this approach could also be applied as a selection criterion as to the suitability of a platform process for the preparation of a new drug candidate. Also the methodology provides means for bioprocess engineers to predict at the discovery phase how a bioprocess will impact upon the quality of the final product. Biotechnol. Bioeng. 2010;107: 85–95. © 2010 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Therapeutic antibodies: successes, limitations and hopes for the future
Chames, P., Van Regenmortel, M., Weiss, E., & Baty, D. (2009) · British Journal of Pharmacology · doi:10.1111/j.1476-5381.2009.00190.x · Cited by 1,382
Cited by
Muneeruddin, K., Nazzaro, M., & Kaltashov, I. A. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b02982 · Cited by 98
Toward Biotherapeutic Product Real‐Time Quality Monitoring
Guerra, A., von Stosch, M., & Glassey, J. (2019) · Critical Reviews in Biotechnology · doi:10.1080/07388551.2018.1524362 · Cited by 58
“vation and the improvement of the measurements frequency as no proteolytic digestion step is required [90,106,107].”
BackgroundMethod
Metadata
- Authors
- Reid, C. Q., Tait, A., Baldascini, H., Mohindra, A., Racher, A., Bilsborough, S., Smales, C. M., & Hoare, M.
- Venue
- Biotechnology and Bioengineering
- Publisher
- Wiley
- Published
- 2010-06-03
- Volume
- 107
- Issue
- 1
- Pages
- 85-95
- ISSN
- 0006-3592 (ISSN-L)
- 1097-0290
- OpenAlex
- W2075316482
- Cited by
- 41
- References
- 1
- FWCI
- 2.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Rapid whole monoclonal antibody analysis by mass spectrometry: An Ultra scale‐down study of the effect of harvesting by centrifugation on the post‐translational modification profile. https://app.cochat.ai/papers/10.1002/bit.22790
- The paper
- Reid, C. Q., Tait, A., Baldascini, H., Mohindra, A., Racher, A., Bilsborough, S., Smales, C. M., & Hoare, M. (2010). Rapid whole monoclonal antibody analysis by mass spectrometry: An Ultra scale‐down study of the effect of harvesting by centrifugation on the post‐translational modification profile. Biotechnology and Bioengineering. https://doi.org/10.1002/bit.22790
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.