Perfusion of 3D encapsulated hepatocytes—A synergistic effect enhancing long‐term functionality in bioreactors
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Long‐term primary cultures of hepatocytes are essential for bioartificial liver (BAL) devices and to reduce and replace animal tests in lead candidate optimization in drug discovery and toxicology tests. The aim of this work was to improve bioreactor cultures of hepatocyte spheroids by adding a more physiological perfusion feeding regime to these bioreactor systems. A continuous perfusion feeding was compared with 50% medium replacement (routinely used for in vitro tests) at the same dilution rate, 0.125 day−1, for three operative weeks. Perfusion feeding led to a 10‐fold improvement in albumin synthesis in bioreactors containing non‐encapsulated hepatocyte spheroids; no significant improvement was observed in phase I drug metabolizing activity. When ultra high viscous alginate encapsulated spheroids were cultured in perfusion, urea synthesis, phase I drug metabolizing activity and oxygen consumption had a threefold improvement over the 50% medium replacement regime; albumin production was the same for both feeding regimes. The effective diffusion of albumin in the alginate capsules was 7.75.10−9 cm 2 s−1 and no diffusion limitation for this protein was observed using these alginate capsules under our operational conditions. In conclusion, perfusion feeding coupled with alginate encapsulation of hepatocyte spheroids showed a synergistic effect with a threefold improvement in three independent liver‐specific functions of long‐term hepatocyte spheroid cultures. Biotechnol. Bioeng. 2011; 108:41–49. © 2010 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bhatia, S. N., Balis, U. J., Yarmush, M. L., & Toner, M. (1999) · The FASEB Journal · doi:10.1096/fasebj.13.14.1883 · Cited by 890 · cited 2×
“Maintaining liver-specific activities of primary cultures of hepatocytes have been attempted in many approaches (reviewed in Berthiaume et al., 1996; Bhatia et al., 1999; Pichard-Garcia et al., 2002; Sivaraman et al., 2005).”
BackgroundMolecular physiology of the regulation of hepatic gluconeogenesis and glycolysis.
Pilkis, S. J., & Granner, D. K. (1992) · Annual Review of Physiology · doi:10.1146/annurev.ph.54.030192.004321 · Cited by 865
LeCluyse, E. L. (2001) · European Journal of Pharmaceutical Sciences · doi:10.1016/s0928-0987(01)00135-x · Cited by 477
Human hepatocytes as a tool for studying toxicity and drug metabolism
Gomez-Lechon, M., Donato, M., Castell, J., & Jover, R. (2003) · Current Drug Metabolism · doi:10.2174/1389200033489424 · Cited by 242
Functional behavior of primary rat liver cells in a three-dimensional perfused microarray bioreactor
Powers, M. J., Janigian, D. M., Wack, K. E., Baker, C. S., Stolz, D. B., & Griffith, L. G. (2002) · Tissue Engineering · doi:10.1089/107632702760184745 · Cited by 234 · cited 1×
“Perfused microbioreactors with increased throughput capability for hepatocyte culture have recently been developed (Carraro et al., 2008; Korin et al., 2009; Park et al., 2008; Powers et al., 2002; Sivaraman et al., 2005; Zhang et al., 2008).”
BackgroundFeng, Z.-Q., Chu, X., Huang, N.-P., Wang, T., Wang, Y., Shi, X., Ding, Y., & Gu, Z.-Z. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.01.053 · Cited by 216 · cited 1×
“Hollow fibers is the most common configuration for hepatocyte culture reactors (De Bartolo et al., 2009; Feng et al., 2009; Flendrig et al., 1997; Patzer, 2004) because these bioreactors offer immunoprotection to the ALF patient due to the separation between the hepatocytes and the culture medium/blood; however, this…”
BackgroundIn vitro analysis of a hepatic device with intrinsic microvascular-based channels
Carraro, A., Hsu, W.-M., Kulig, K. M., Cheung, W. S., Miller, M. L., Weinberg, E. J., Swart, E. F., Kaazempur-Mofrad, M., Borenstein, J. T., Vacanti, J. P., et al. (2008) · Biomedical Microdevices · doi:10.1007/s10544-008-9194-3 · Cited by 168
Cited by
Godoy, P., Hewitt, N. J., Albrecht, U., Andersen, M. E., Ansari, N., Bhattacharya, S., Bode, J. G., Bolleyn, J., Borner, C., Böttger, J., et al. (2013) · Archives of Toxicology · doi:10.1007/s00204-013-1078-5 · Cited by 1,280
Hickman, J. A., Graeser, R., de Hoogt, R., Vidic, S., Brito, C., Gutekunst, M., van der Kuip, H., & IMI PREDECT consortium (2014) · Biotechnology Journal · doi:10.1002/biot.201300492 · Cited by 380
Organotypic liver culture models: meeting current challenges in toxicity testing
LeCluyse, E. L., Witek, R. P., Andersen, M. E., & Powers, M. J. (2012) · Critical Reviews in Toxicology · doi:10.3109/10408444.2012.682115 · Cited by 363
Santos, J. M., Camões, S. P., Filipe, E., Cipriano, M., Barcia, R. N., Filipe, M., Teixeira, M., Simões, S., Gaspar, M., Mosqueira, D., et al. (2015) · Stem Cell Research & Therapy · doi:10.1186/s13287-015-0082-5 · Cited by 196
“Alternatively, a less complex three-dimensional model is the spinner flask suspension culture (SFSC), where cells self-assemble into spheroid-like structures, thus enabling greater cellcell and cell-matrix interactions [19-22,25-27].”
BackgroundSelf-citationA critical perspective on 3D liver models for drug metabolism and toxicology studies
Serras, A. S., Rodrigues, J. S., Cipriano, M., Rodrigues, A. V., Oliveira, N. G., & Miranda, J. P. (2021) · Frontiers in Cell and Developmental Biology · doi:10.3389/fcell.2021.626805 · Cited by 138
Self-citationLi, C. Y., Stevens, K. R., Schwartz, R. E., Alejandro, B. S., Huang, J. H., & Bhatia, S. N. (2014) · Tissue Engineering Part A · doi:10.1089/ten.tea.2013.0667 · Cited by 132
Abecasis, B., Aguiar, T., Arnault, É., Costa, R., Gomes-Alves, P., Aspegren, A., Serra, M., & Alves, P. M. (2017) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2017.01.004 · Cited by 100
Self-citationEffect of plasma components on the stability and permeability of microcapsule
Chen, L., Zhang, Y., Li, S., Wang, X., Li, N., Wang, Y., Guo, X., Zhao, S., Yu, W., Sun, G., et al. (2014) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.34907 · Cited by 10
“Thus, in vivo-like cytoarchitecture can be achieved with viability as well as the metabolic, synthetic, and detoxificatory activities of encapsulated hepatocytes well maintained.(17) In addition, the spherical configuration of microcapsules offer a higher ratio of surface area to volume for mass transportation and the…”
Background
Metadata
- Authors
- Tostões, R. M., Leite, S. B., Miranda, J. P., Sousa, M., Wang, D. I. C., Carrondo, M. J. T., & Alves, P. M.
- Venue
- Biotechnology and Bioengineering
- Publisher
- Wiley
- Published
- 2010-09-30
- Volume
- 108
- Issue
- 1
- Pages
- 41-49
- ISSN
- 0006-3592 (ISSN-L)
- 1097-0290
- OpenAlex
- W2078388258
- Cited by
- 86
- References
- 7
- FWCI
- 9.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.