CoChat

In vitro analysis of a hepatic device with intrinsic microvascular-based channels

The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.

Abstract

A novel microfluidics-based bilayer device with a discrete parenchymal chamber modeled upon hepatic organ architecture is described. The microfluidics network was designed using computational models to provide appropriate flow behavior based on physiological data from human microvasculature. Patterned silicon wafer molds were used to generate films with the vascular-based microfluidics network design and parenchymal chamber by soft lithography. The assembled device harbors hepatocytes behind a nanoporous membrane that permits transport of metabolites and small proteins while protecting them from the effects of shear stress. The device can sustain both human hepatoma cells and primary rat hepatocytes by continuous in vitro perfusion of medium, allowing proliferation and maintaining hepatic functions such as serum protein synthesis and metabolism. The design and fabrication processes are scalable, enabling the device concept to serve as both a platform technology for drug discovery and toxicity, and for the continuing development of an improved liver-assist device.

Overview

Integrity signals

Registry

Crossref · 10.1007/s10544-008-9194-3

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 23 references

Research works printed but not linked: 2

  1. M.F. Kiani, A.R. Pries, L.L. Hsu, I.H. Sarelius, G.R. Cokelet, Am. J. Physiol. 266(5 Pt 2), H1822–H1828 (1994)
  2. A.R. Pries, D. Neuhaus, P. Gaehtgens, Am. J. Physiol. 263(6 Pt 2), H1770–H1778 (1992)

Cited by

See all 172

Metadata

Authors
Carraro, A., Hsu, W.-M., Kulig, K. M., Cheung, W. S., Miller, M. L., Weinberg, E. J., Swart, E. F., Kaazempur-Mofrad, M., Borenstein, J. T., Vacanti, J. P., & Neville, C.
Affiliations
  • University of Padua (IT)
  • Massachusetts General Hospital (US)
  • Harvard University (US)
  • Draper Laboratory (US)
Corresponding author
Neville, Craig
Venue
Biomedical Microdevices
Published
2008-07-05
Volume
10
Issue
6
Pages
795-805
ISSN
  • 1387-2176 (ISSN-L)
  • 1572-8781
OpenAlex
W2031785809
Cited by
168
References
23
Citations by year
2026: 2 · 2025: 2 · 2024: 1 · 2023: 9 · 2022: 11 · 2021: 8 · 2020: 4 · 2019: 7 · 2018: 7 · 2017: 5 · 2016: 14 · 2015: 8 · 2014: 13 · 2013: 19 · 2012: 11
FWCI
10.39
Type
journal article
Language
en
Open access
closed
Licence
www.springer.com/tdm (tdm)
Locations
  • Biomedical Microdevices (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
  • Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
Keywords
bilayer devices, soft lithography, nanoporous membranes, hepatocyte culture, hepatoma cells, primary rat hepatocytes, serum protein synthesis, drug discovery, toxicity testing, artificial liver support
MeSH terms
Animals, Drug Evaluation, Preclinical, Humans, Male, Membranes, Artificial, Rats, Inbred Lew, Silicon, Porosity, Cell Culture Techniques, Liver, Artificial, Hepatocytes, Cell Line, Tumor, Microfluidic Analytical Techniques, Rats

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: In vitro analysis of a hepatic device with intrinsic microvascular-based channels. https://app.cochat.ai/papers/10.1007/s10544-008-9194-3
The paper
Carraro, A., Hsu, W.-M., Kulig, K. M., Cheung, W. S., Miller, M. L., Weinberg, E. J., Swart, E. F., Kaazempur-Mofrad, M., Borenstein, J. T., Vacanti, J. P., & Neville, C. (2008). In vitro analysis of a hepatic device with intrinsic microvascular-based channels. Biomedical Microdevices. https://doi.org/10.1007/s10544-008-9194-3

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.