Selective high throughput protein quantification based on UV absorption spectra
The DOI matches its Crossref record.
Abstract
The application of high throughput experimentation (HTE) in protein purification process development has created an analytical bottleneck. Recently, a new label‐free and non‐invasive methodology for analyzing multicomponent protein mixtures by means of spectral measurements was presented. Analytics based on the methodology was shown to increase analytical throughput for selective protein quantification significantly, however this was only demonstrated for one particular protein combination. In this work, the possibilities and limitations of the analytical method are investigated further. Principal component analysis (PCA) was performed on a broad range of absorption spectra to investigate their common characteristics and differences. The PCA was used both for cluster analysis and to define a measure for spectral similarity. For binary protein combinations, the calibration precision was shown to decrease exponentially with the defined spectral similarity factor. Knowledge of this correlation can be used to determine a priori whether a calibration will be successful or not. Calibration robustness was investigated by applying the analytics to liquid chromatography performed in HTE mode. Further it was shown, that a spectral difference of 0.6% was sufficient to sucessfully preform a spectral based calibration of two IgG1 monoclonals. Biotechnol. Bioeng. 2013; 110: 448–460. © 2012 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Claßen, J., Aupert, F., Reardon, K. F., Solle, D., & Scheper, T. (2017) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-016-0068-x · Cited by 176
Modern Sensor Tools and Techniques for Monitoring, Controlling, and Improving Cell Culture Processes
Reyes, S. J., Durocher, Y., Pham, P. L., & Henry, O. (2022) · Processes · doi:10.3390/pr10020189 · Cited by 130
Rolinger, L., Rüdt, M., & Hubbuch, J. (2020) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-020-02407-z · Cited by 126
Self-citationMini‐review: soft sensors as means for PAT in the manufacture of bio‐therapeutics
Mandenius, C., & Gustavsson, R. (2015) · Journal of Chemical Technology & Biotechnology · doi:10.1002/jctb.4477 · Cited by 84
Metadata
- Authors
- Hansen, S. K., Jamali, B., & Hubbuch, J.
- Venue
- Biotechnology and Bioengineering
- Publisher
- Wiley
- Published
- 2012-09-18
- Volume
- 110
- Issue
- 2
- Pages
- 448-460
- ISSN
- 0006-3592 (ISSN-L)
- 1097-0290
- OpenAlex
- W1964709462
- Cited by
- 55
- References
- 0
- FWCI
- 2.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Selective high throughput protein quantification based on UV absorption spectra. https://app.cochat.ai/papers/10.1002/bit.24712
- The paper
- Hansen, S. K., Jamali, B., & Hubbuch, J. (2013). Selective high throughput protein quantification based on UV absorption spectra. Biotechnology and Bioengineering. https://doi.org/10.1002/bit.24712
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.