Microfluidic culture models to study the hydrodynamics of tumor progression and therapeutic response
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
The integration of tissue engineering strategies with microfluidic technologies has enabled the design of in vitro microfluidic culture models that better adapt to morphological changes in tissue structure and function over time. These biomimetic microfluidic scaffolds accurately mimic native 3D microenvironments, as well as permit precise and simultaneous control of chemical gradients, hydrodynamic stresses, and cellular niches within the system. The recent application of microfluidic in vitro culture models to cancer research offers enormous potential to aid in the development of improved therapeutic strategies by supporting the investigation of tumor angiogenesis and metastasis under physiologically relevant flow conditions. The intrinsic material properties and fluid mechanics of microfluidic culture models enable high‐throughput anti‐cancer drug screening, permit well‐defined and controllable input parameters to monitor tumor cell response to various hydrodynamic conditions or treatment modalities, as well as provide a platform for elucidating fundamental mechanisms of tumor physiology. This review highlights recent developments and future applications of microfluidic culture models to study tumor progression and therapeutic targeting under conditions of hydrodynamic stress relevant to the complex tumor microenvironment. Biotechnol. Biotechnol. Bioeng. 2013; 110: 2063–2072. © 2013 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chaotic Mixer for Microchannels
Stroock, A. D., Dertinger, S. K. W., Ajdari, A., Mezić, I., Stone, H. A., & Whitesides, G. M. (2002) · Science · doi:10.1126/science.1066238 · Cited by 3,435 · cited 1×
“Compared to their behavior at themacroscale, fluids at microscale volumes are dominated by viscous rather than inertial forces (Beebe et al., 2002; Stroock et al., 2002).”
BackgroundDrug Resistance and the Solid Tumor Microenvironment
Tredan, O., Galmarini, C. M., Patel, K., & Tannock, I. F. (2007) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/djm135 · Cited by 2,116 · cited 2×
“…a matrix of collagens, proteoglycans, and other molecules that hinder the transport Buchanan and Rylander: Tumor Progression and Therapeutic Response 2067 Biotechnology and Bioengineering of high molecular weight macromolecules into the tumor interstitium (Netti et al., 2000; Tredan et al., 2007).”
BackgroundThree-dimensional microfluidic model for tumor cell intravasation and endothelial barrier function
Zervantonakis, I. K., Hughes-Alford, S. K., Charest, J. L., Condeelis, J. S., Gertler, F. B., & Kamm, R. D. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1210182109 · Cited by 872 · cited 4×
“This configuration enables the investigation of transvascular and interstitial fluid flow on endothelial cell migration kinetics, barrier function, and chemotaxis relevant to the tumor microenvironment (Chung et al., 2009; Farahat et al., 2012; Shin et al., 2012; Vickerman and Kamm, 2012; Vickerman et al., 2008; Zerva…”
BackgroundInfluentialBarry-Hamilton, V., Spangler, R., Marshall, D., McCauley, S., Rodriguez, H. M., Oyasu, M., Mikels, A., Vaysberg, M., Ghermazien, H., Wai, C., et al. (2010) · Nature Medicine · doi:10.1038/nm.2208 · Cited by 870
Lymphatic and interstitial flow in the tumour microenvironment: linking mechanobiology with immunity
Swartz, M. A., & Lund, A. W. (2012) · Nature Reviews Cancer · doi:10.1038/nrc3186 · Cited by 544 · cited 1×
“As a result, non-uniform cytokine gradients and abnormal flow shear stresses are present, which can greatly influence tumor and stromal cell behavior, immune response, as well as delivery and efficacy of therapeutic modalities (Swartz and Lund, 2012).”
BackgroundInterstitial flow influences direction of tumor cell migration through competing mechanisms
Polacheck, W. J., Charest, J. L., & Kamm, R. D. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1103581108 · Cited by 509 · cited 3×
“In addition, recently published work by Polacheck et al. (2011) has further demonstrated the capacity of these microfluidic scaffolds to investigate the influence of interstitial flow on tumor cell migration.”
BackgroundMethodFluid forces control endothelial sprouting
Song, J. W., & Munn, L. L. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1105316108 · Cited by 498 · cited 2×
“Pioneering efforts have also been made by Song et al. utilizing microfluidic devices to model interactions between the endothelium and circulating tumor cells, as well as the effect of flow shear stress on angiogenesis (Song and Munn, 2011; Song et al., 2009, 2012).”
BackgroundInfluentialMicrofluidic Endothelium for Studying the Intravascular Adhesion of Metastatic Breast Cancer Cells
Song, J. W., Cavnar, S. P., Walker, A. C., Luker, K. E., Gupta, M., Tung, Y.-C., Luker, G. D., & Takayama, S. (2009) · PLoS ONE · doi:10.1371/journal.pone.0005756 · Cited by 317
Sung, K. E., Yang, N., Pehlke, C., Keely, P. J., Eliceiri, K. W., Friedl, A., & Beebe, D. J. (2011) · Integr. Biol. · doi:10.1039/c0ib00063a · Cited by 226 · cited 1×
“…as a function of substrate stiffness (Chicurel, 2002; Chung et al., 2009) or growth factor gradients (Liu et al., 2009; Shin et al., 2011), as well as mechanisms of tumor cell deformation and extravasation important in metastasis (Chaw et al., 2007; Sung et al., 2011; Zervantonakis et al., 2012).”
BackgroundMigration dynamics of breast cancer cells in a tunable 3D interstitial flow chamber
Haessler, U., Teo, J. C. M., Foretay, D., Renaud, P., & Swartz, M. A. (2012) · Integrative Biology · doi:10.1039/c1ib00128k · Cited by 176
Cited by
Antoine, E. E., Vlachos, P. P., & Rylander, M. N. (2014) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2014.0086 · Cited by 611
Self-citationChwalek, K., Bray, L. J., & Werner, C. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2014.05.006 · Cited by 91
Microfluidic system for modelling 3D tumour invasion into surrounding stroma and drug screening
Du, Z., Mi, S., Yi, X., Xu, Y., & Sun, W. (2018) · Biofabrication · doi:10.1088/1758-5090/aac70c · Cited by 42
In vitro micro-physiological models for translational immunology
Ramadan, Q., & Gijs, M. A. M. (2015) · Lab on a Chip · doi:10.1039/c4lc01271b · Cited by 41
Metadata
- Authors
- Buchanan, C., & Rylander, M. N.
- Venue
- Biotechnology and Bioengineering
- Publisher
- Wiley
- Published
- 2013-06-15
- Volume
- 110
- Issue
- 8
- Pages
- 2063-2072
- ISSN
- 0006-3592 (ISSN-L)
- 1097-0290
- OpenAlex
- W2166469766
- Cited by
- 34
- References
- 12
- FWCI
- 2.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.