Semisynthetic model calibration for monitoring glucose in mammalian cell culture with in situ near infrared spectroscopy
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Near infrared (NIR) spectroscopy has the capability of providing real‐time, multi‐analyte monitoring of the complex reaction mixture associated with cell culture processes. However, the development of robust models to predict the concentration of key analytes has proven difficult. In this study, a modeling methodology using semisynthetic process samples was used to predict glucose concentrations in Chinese Hamster Ovary (CHO) cell culture processes. Partial Least Squares (PLS) regression models were built from in situ NIR spectra, and glucose levels between 4.0 and 14.0 g/L. Two models were constructed. The “standard model” used data provided by cell culture production process samples. The “full model” included the data provided from both cell culture production process samples and semisynthetic samples. The semisynthetic samples were generated by titrating cell culture samples with target viable cell density (VCD) and lactate levels to defined glucose concentrations. The robustness of each model was gauged by predicting glucose in a subsequent cell culture process utilizing a media formulation and cell line not contained in the calibration data sets. The “full model” generated glucose predictions with a root mean square error of prediction (RMSEP) of 0.99 g/L while the “standard model” provided glucose predictions with a RMSEP of 2.26 g/L. The modeling approach utilizing semisynthetic samples proved to be faster development and more effective than using just standard cell culture processes. Biotechnol. Biotechnol. Bioeng. 2014;111: 896–903. © 2013 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Near Infrared Spectroscopy for Bioprocess Monitoring and Control: Current Status and Future Trends
Scarff, M., Arnold, S. A., Harvey, L. M., & McNeil, B. (2006) · Critical Reviews in Biotechnology · doi:10.1080/07388550500513677 · Cited by 124 · cited 1×
“DOI 10.1002/bit.25161 896 Biotechnology and Bioengineering, Vol. 111, No. 5, May, 2014 2013 Wiley Periodicals, Inc. et al., 2006; Finn et al., 2006; Rhiel et al., 2001; Roychoudhury et al., 2007; Scarff et al., 2006; Tamburini et al., 2003).”
Influential
Cited by
Sensor systems for bioprocess monitoring
Biechele, P., Busse, C., Solle, D., Scheper, T., & Reardon, K. (2015) · Engineering in Life Sciences · doi:10.1002/elsc.201500014 · Cited by 224
“Pilot tests, spiking experiments, and data from experimental design allow one to construct premodels, which can be adjusted and validated by process data [213, 214].”
MethodAdvances in process monitoring tools for cell culture bioprocesses
Zhao, L., Fu, H., Zhou, W., & Hu, W. (2015) · Engineering in Life Sciences · doi:10.1002/elsc.201500006 · Cited by 81
Rowland‐Jones, R. C., van den Berg, F., Racher, A. J., Martin, E. B., & Jaques, C. (2017) · Biotechnology Progress · doi:10.1002/btpr.2459 · Cited by 48
Developing global regression models for metabolite concentration prediction regardless of cell line
André, S., Lagresle, S., Da Sliva, A., Heimendinger, P., Hannas, Z., Calvosa, É., & Duponchel, L. (2017) · Biotechnology and Bioengineering · doi:10.1002/bit.26368 · Cited by 47
“In pursuit of the same goal, Milligan et al. (2014) have proposed to merge on-line and off-line measurements in a unique calibration dataset in order to develop “semi-synthetic” models.”
Background
Metadata
- Authors
- Milligan, M., Lewin‐Koh, N., Coleman, D., Arroyo, A., & Saucedo, V.
- Venue
- Biotechnology and Bioengineering
- Publisher
- Wiley
- Published
- 2013-12-17
- Volume
- 111
- Issue
- 5
- Pages
- 896-903
- ISSN
- 0006-3592 (ISSN-L)
- 1097-0290
- OpenAlex
- W1859076399
- Cited by
- 16
- References
- 1
- FWCI
- 2.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.