CoChat

Insulin receptor antibody‐iduronate 2‐sulfatase fusion protein: Pharmacokinetics, anti‐drug antibody, and safety pharmacology in Rhesus monkeys

Open access
Boado, Ruben J., Ka‐Wai Hui, Eric, Zhiqiang Lu, Jeff, Pardridge, William M. · 2014 · Biotechnology and Bioengineering
Cited by 106

The DOI matches its Crossref record.

Abstract

Mucopolysaccharidosis (MPS) Type II is caused by mutations in the gene encoding the lysosomal enzyme, iduronate 2‐sulfatase (IDS). The majority of MPSII cases affect the brain. However, enzyme replacement therapy with recombinant IDS does not treat the brain, because IDS is a large molecule drug that does not cross the blood‐brain barrier (BBB). To enable BBB penetration, IDS has been re‐engineered as an IgG‐IDS fusion protein, where the IgG domain is a monoclonal antibody (MAb) against the human insulin receptor (HIR). The HIRMAb crosses the BBB via receptor‐mediated transport on the endogenous BBB insulin receptor, and the HIRMAb domain of the fusion protein acts as a molecular Trojan horse to ferry the fused IDS into brain from blood. The present study reports on the first safety pharmacology and pharmacokinetics study of the HIRMAb‐IDS fusion protein. Juvenile male Rhesus monkeys were infused intravenously (IV) weekly for 26 weeks with 0, 3, 10, or 30 mg/kg of the HIRMAb‐IDS fusion protein. The plasma clearance of the fusion protein followed a linear pharmacokinetics profile, which was equivalent either with measurements of the plasma concentration of immunoreactive HIRMAb‐IDS fusion protein, or with assays of plasma IDS enzyme activity. Anti‐drug antibody (ADA) titers were monitored monthly, and the ADA response was primarily directed against the variable region of the HIRMAb domain of the fusion protein. No infusion related reactions or clinical signs of immune response were observed during the course of the study. A battery of safety pharmacology, clinical chemistry, and tissue histopathology showed no signs of adverse events, and demonstrate the safety profile of chronic treatment of primates with 3–30 mg/kg weekly IV infusion doses of the HIRMAb‐IDS fusion protein. Biotechnol. Bioeng. 2014;111: 2317–2325. © 2014 Wiley Periodicals, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/bit.25289

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Boado, R. J., Ka‐Wai Hui, E., Zhiqiang Lu, J., & Pardridge, W. M.
Venue
Biotechnology and Bioengineering
Publisher
Wiley
Published
2014-08-05
Volume
111
Issue
11
Pages
2317-2325
ISSN
  • 0006-3592 (ISSN-L)
  • 1097-0290
OpenAlex
W2137541358
Cited by
106
References
0
FWCI
6.22
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.