CoChat

Inner filter effects and their interferences in the interpretation of culture fluorescence

Srinivas, S. P., Mutharasan, R. · 1987 · Biotechnology and Bioengineering
Cited by 69

The DOI matches its Crossref record.

Abstract

Inner filter effects and their interferences in the measurement and interpretation of culture fluorescence are discussed. An approximate light intensity model for a typical open‐ended culture fluorescence measuring device is developed for calculating the fluorescence response of a component of interest in a general three component solution. The model is tested using well de fined synthetic fluorescent systems. The model is then extended for correlating culture fluorescence with cell density and metabolic state of microbial cultures based on a lumping approximation. The extended model has been utilized to derive culture fluorescence parameters of yeast culture at three distinct metabolic states.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/bit.260300609

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 69

Metadata

Authors
Srinivas, S. P., & Mutharasan, R.
Venue
Biotechnology and Bioengineering
Publisher
Wiley
Published
1987-10-20
Volume
30
Issue
6
Pages
769-774
ISSN
  • 0006-3592 (ISSN-L)
  • 1097-0290
OpenAlex
W2092990113
Cited by
69
References
0
FWCI
9.51
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Inner filter effects and their interferences in the interpretation of culture fluorescence. https://app.cochat.ai/papers/10.1002/bit.260300609
The paper
Srinivas, S. P., & Mutharasan, R. (1987). Inner filter effects and their interferences in the interpretation of culture fluorescence. Biotechnology and Bioengineering. https://doi.org/10.1002/bit.260300609

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.