Use of fluorometry for monitoring and control of a bioreactor
The DOI matches its Crossref record.
Abstract
A new fluorescent bioreactor monitoring probe—multiple excitation fluorometric system (MEFS)—has been developed. This probe was compared to the commercially available BioChem Technology FluroMeasure system (NADH probe). In this task the fluorescence behavior of three model fermentation systems, ethanol fermentation by Candida utilis, phenol fermentation by Pseudomonas putida, and glucose fermentation by Saccharomyces cerevisiae, were examined. The results indicated that the fluorescence intensity and behavior of various cellular fluorophors vary significantly between the different fermentation systems. Monitoring a fermentation process using only NAD(P)H fluorescence provided limited information. The NAD(P)H fluorescence was found not to be the best fluorescence signal for monitoring cell concentrations. The best way of monitoring a bioreactor by fluorometry may be to monitor several fluorophors in the whole culture broth simultaneously and to relate these fluorescence signals to various biological parameters.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Progress in monitoring, modeling and control of bioprocesses during the last 20 years
Schügerl, K. (2001) · Journal of Biotechnology · doi:10.1016/s0168-1656(00)00361-8 · Cited by 278
Fluorescence Spectroscopy and Chemometric Modeling for Bioprocess Monitoring
Faassen, S., & Hitzmann, B. (2015) · Sensors · doi:10.3390/s150510271 · Cited by 120
“Furthermore, the culture fluorescence depends on bioprocess variables, such as the optical density (OD), viscosity, pH, the aeration of the bioreactor and a lot of further the fluorescence measurements affecting variables [22].”
BackgroundIn situ 2D fluorometry and chemometric monitoring of mammalian cell cultures
Teixeira, A. P., Portugal, C. A. M., Carinhas, N., Dias, J. M. L., Crespo, J. P., Alves, P. M., Carrondo, M. J. T., & Oliveira, R. (2009) · Biotechnology and Bioengineering · doi:10.1002/bit.22125 · Cited by 90
Observations of fluorescent and biological aerosol at a high-altitude site in central France
Gabey, A. M., Vaitilingom, M., Freney, E., Boulon, J., Sellegri, K., Gallagher, M. W., Crawford, I. P., Robinson, N. H., Stanley, W. R., & Kaye, P. H. (2013) · Atmospheric Chemistry and Physics · doi:10.5194/acp-13-7415-2013 · Cited by 64
(2017) · PubMed
Metadata
- Authors
- Li, J., & Humphrey, A. E.
- Venue
- Biotechnology and Bioengineering
- Publisher
- Wiley
- Published
- 1991-05
- Volume
- 37
- Issue
- 11
- Pages
- 1043-1049
- ISSN
- 0006-3592 (ISSN-L)
- 1097-0290
- OpenAlex
- W2026546169
- Cited by
- 95
- References
- 0
- FWCI
- 9.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.