Hepatocyte culture on biodegradable polymeric substrates
The DOI matches its Crossref record.
Abstract
The interactions of primary rat liver cells with biodegradable polymeric substrates were investigated in vitro to assess the suitability of the polymer materials for use in cell transplantation devices. The kinetics of cell adhesion to, and the growth and biochemical function of cells maintained on, films formed from poly (D,L‐lactic‐co‐glycolic acid, 88: 12) (PLGA) or from a 50/50 (w/w) blend of PLGA and poly (L‐lactic acid) (PLLA) were evaluated in comparison to two control substrates, matrigel coated or collagen‐coated polystyrene petri dishes. The rate of cell adhesion to both types of polymeric substrates was similar to the rate of adhesion to the collagen control substrate, but of the two polymers, only the blend was suitable for extended culture. Hepatocytes maintained on the polymer blend films showed retention of differentiated cell function as measured by the rate of albumin secretion–the rate of albumin secretion by cells on the films was the same as the rate for cells on matrigel and reached a level in the range of reported in vivo levels (140–160 μg/10 6 cells/24 h). In contrast, albumin secretion by hepatocytes maintained on collagen‐coated polystyrene culture dishes declined over five days to a level one third that of the initial level and one fifth that of cells maintained on the polymer blend films on day five. Such retention of differentiated cell function by hepatocytes in culture has previously been observed only when hepatocytes were cultured in the presence of exogenous extracellular matrix proteins or were cocultured with another cell type. In addition to retention of differentiated function, the cells maintained on the polymer blend films also displayed rates of DNA synthesis similar to controls maintained on collagen‐coated polystyrene, a substrate optimal for DNA synthesis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The design of scaffolds for use in tissue engineering. Part I. Traditional factors
Yang, S., Leong, K.-F., Du, Z., & Chua, C.-K. (2001) · Tissue Engineering · doi:10.1089/107632701753337645 · Cited by 2,234
Preparation and characterization of poly(l-lactic acid) foams
Mikos, A. G., Thorsen, A. J., Czerwonka, L. A., Bao, Y., Langer, R., Winslow, D. N., & Vacanti, J. P. (1994) · Polymer · doi:10.1016/0032-3861(94)90953-9 · Cited by 1,187
Self-citationThe Design of Scaffolds for Use in Tissue Engineering. Part II. Rapid Prototyping Techniques
Yang, S., Leong, K.-F., Du, Z., & Chua, C.-K. (2002) · Tissue Engineering · doi:10.1089/107632702753503009 · Cited by 729
Mann, B. K., Gobin, A. S., Tsai, A. T., Schmedlen, R. H., & West, J. L. (2001) · Biomaterials · doi:10.1016/s0142-9612(01)00051-5 · Cited by 704
Laminated three-dimensional biodegradable foams for use in tissue engineering
Mikos, A. G., Sarakinos, G., Leite, S. M., Vacant, J. P., & Langer, R. (1993) · Biomaterials · doi:10.1016/0142-9612(93)90049-8 · Cited by 666
Self-citation
Metadata
- Authors
- Cima, L. G., Ingber, D. E., Vacanti, J. P., & Langer, R.
- Venue
- Biotechnology and Bioengineering
- Publisher
- Wiley
- Published
- 1991-06-20
- Volume
- 38
- Issue
- 2
- Pages
- 145-158
- ISSN
- 0006-3592 (ISSN-L)
- 1097-0290
- OpenAlex
- W2139438415
- Cited by
- 137
- References
- 0
- FWCI
- 14.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hepatocyte culture on biodegradable polymeric substrates. https://app.cochat.ai/papers/10.1002/bit.260380207
- The paper
- Cima, L. G., Ingber, D. E., Vacanti, J. P., & Langer, R. (1991). Hepatocyte culture on biodegradable polymeric substrates. Biotechnology and Bioengineering. https://doi.org/10.1002/bit.260380207
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.