On‐line characterization of a hybridoma cell culture process
The DOI matches its Crossref record.
Abstract
The on‐line determination of the physiological state of a cell culture process requires reliable on‐line measurements of various parameters and calculations of specific rates from these measurements. The cell concentration of a hybridoma culture was estimated on‐line by measuring optical density (OD) with a laser turbidity probe. The oxygen uptake rate (OUR) was determined by monitoring dynamically dissolved oxygen concentration profiles and closing oxygen balances in the culture. The base addition for neutralizing lactate produced by cells was also monitored on‐line via a balance. Using OD and OUR measurements, the specific growth and specific oxygen consumption rates were determined on‐line. By combining predetermined stoichiometric relationships among oxygen and glucose consumption and lactate production, the specific glucose consumption and lactate production rates were also calculated on‐line. Using these on‐line measurements and calculations, the hybridoma culture process was characterized on‐line by identifying the physiological states. They will also facilitate the implementation of nutrient feeding strategies for fed‐batch and perfusion cultures. © 1994 John Wiley & Sons, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Carvell, J. P., & Dowd, J. E. (2006) · Cytotechnology · doi:10.1007/s10616-005-3974-x · Cited by 184
“Laser turbidity probes have been used in batch culture (Konstantinov et al. 1992; Zho and Hu 1994; Wu et al. 1995) and the probe performance in general is acceptable for high viability cultures.”
MethodCO2 in large-scale and high-density CHO cell perfusion culture
Gray, D. R., Chen, S., Howarth, W., Inlow, D., & Maiorella, B. L. (1996) · Cytotechnology · doi:10.1007/bf00353925 · Cited by 176
Advances in process monitoring tools for cell culture bioprocesses
Zhao, L., Fu, H., Zhou, W., & Hu, W. (2015) · Engineering in Life Sciences · doi:10.1002/elsc.201500006 · Cited by 81
“For in-line measurement of cell concentration, turbidity measurement has long been used [55, 56] and commercially available probes are available.”
MethodSelf-citationKonakovsky, V., Clemens, C., Müller, M., Bechmann, J., Berger, M., Schlatter, S., & Herwig, C. (2016) · Bioengineering · doi:10.3390/bioengineering3010005 · Cited by 44
“Zhou and Hu first mention signals which may be used to detect the metabolic state of mammalian cell cultures and derive a feeding profile on-line [46].”
Background
Metadata
- Authors
- Zhou, W., & Hu, W.
- Venue
- Biotechnology and Bioengineering
- Publisher
- Wiley
- Published
- 1994-06-20
- Volume
- 44
- Issue
- 2
- Pages
- 170-177
- ISSN
- 0006-3592 (ISSN-L)
- 1097-0290
- OpenAlex
- W2088073724
- Cited by
- 110
- References
- 0
- FWCI
- 9.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.